LIMIT SWITCH FIXING

The gate has to be equipped with stop locks at the opening and closing, which
prevent the gate derailment.
The stop lock position must assure that the limit switch brackets don't collide with
the pinion gear.
Haul the gate manually at the opening leaving, depending on the gate weight,
a crack from 30 to 50 mm between the main gate and mechanical stop.
Fasten the limit switch bracket through the dowels (fig.11) so that the micri-limit
switch is pressed (fig.10).
Repeat the operation with the main gate at the closing.
fig.11
fig.10
9

INSTALACION

Respetando las dimensiones totales, fijar en el piso la placa de base por medio
de 4 sólidos tornillos de expansión (fig.3) o embeberla en el hormigón (fig. 4).
Predisponer una o varias para el paso de los cables eléctricos.
7 7
fig.3
N.B. Es necesario conocer las dimensiones de la cremallera para poder calcular
con precisión el posicionamiento de la contraplaca.
3 2 0
1 6 0
fig.4