DIMENSIONES TOTALES
47
47
320
320
FUNCIONAMIENTO MANUAL
1 > Introducir la llave y girarla
en sentido antihorario de 90°.
2 > Jalar hacia sí el tirador hasta
llevarlo perpendicular al
motorreductor.
Es oportuno leer atentamente las instrucciones antes de efectuar la instalación.
La falta de observancia de las instrucciones arriba citadas, el uso impropio o
un error de conexión podría perjudicar la seguridad o el funcionamiento
correcto del dispositivo y por lo tanto de toda la instalación.
Se rechaza toda responsabilidad por posibles funcionamientos incorrectos y/o
daños causados por su inobservancia.
La empresa se reserva el derecho de llevar modificaciones al producto.
184
184
28
28
6 5
MAINTENANCE
DANGER: for any maintenance, strike off the supply.
The gear-motor is supplied with permanent grease lubrification and then it
doesn't require any maintenance.
For a correct system maintenance, where the gear-motor is inserted, carry
on as follows: clean and free periodically the runner and relative wheels
by the debris.
DISPOSAL
The material removal has to be carried out observing the current laws.
FINAL RECOMMENDATIONS
1_Carry out the grounging.
2_Keep always apart the feeding cables from the bowden control cables.
3_Equip the system with safety devices as:
When the system overlooks a public street, it is necessary to install two of the above
mentioned devices at least (chosen among three models or also of the same type).
4_For the release it is necessary that the gate, when it is closed, doesn't push on the
stop ledges.
5_Carry out the system according to the current regulations.
6_The thrust force check must be given from the presence within the system of a
couple signaller.
7_It is absolutely necessary, the gate is equipped with the stop ledges, before the
gear-motor is installed.
8_According to the current regulations, the gate thrust force doesn't exceed 15daN.
For the setting check, make use of a dynamometer.
9_Any intervention of maintenance, repair and regulation have to be carried out by
qualified personnel.
No starting before the machine, where it will be inbuilt,
has been declared in compliance with the regulations
of the CEE rules 1998, June 22nd., n° 0037.
-photocells
-couple limiting devices
-sensible rib
6 1 0
GB