wireless remote control of one or several slave flash units by one master or con-
troller flash unit on the camera (for example, mecablitz 58 AF-1N) is possible.
A slave flash unit can be assigned to one of three possible slave groups
(GROUP A, B or C). The master or controller flash unit can control all of these
slave groups simultaneously and at the same time take the settings for each sla-
ve group into account.
So that multiple remote systems in the same room do not interfere with one
another, there are four independent remote channels available (CH 1, 2, 3 or
4). Master, controller and slave flash units belonging to the same remote system
must be set to the same remote channel. The slave flash units must be able to
receive the light from the master or controller flash unit with the integrated sen-
sors for the remote mode
.
Depending on the camera model, the camera's internal flash unit can
also function as master or controller flash unit. Please consult the respec-
tive camera operating instructions for further tips on setting the master
or controller flash unit.
Setting procedure for remote slave flash mode
• Press the button combination „Select" until „
• Apply the setting desired with the buttons ( + ) and ( - ).
- When „On" is displayed, the remote slave mode is activated.
- When „OFF" is displayed, the remote slave mode is deactivated.
The setting takes effect immediately. After about 5 seconds the display stops
flashing and the setting is saved automatically. After activation of the remote
SL
slave mode, „
" appears in the display. In addition, the slave group (GROUP)
selected and the remote channel (CH) are shown.
Setting of the slave group
With the remote slave mode activated, press the button combination „Select"
until „GROUP" (= slave group) flashes in the display. Apply the setting desired
with the buttons ( + ) and ( - ). Selection of group A, B or C is possible.
SL
" flashes in the display.
The setting takes effect immediately. After about 5 seconds the display stops
flashing and the setting is saved automatically. After activation of the remote
SL
slave mode, „
" appears in the display. In addition, the slave group (GROUP)
selected and the remote channel (CH) are shown.
Setting of the remote channel
The same remote channel must be set on the slave flash unit as on the
master or controller flash unit!
• With the remote slave mode activated, press the button combination „Select"
until „CH" (= remote channel) flashes in the display.
• Apply the setting desired with the buttons ( + ) and ( - ). Selection of group 1,
2, 3 or 4 is possible.
The setting takes effect immediately. After about 5 seconds the display stops
flashing and the setting is saved automatically. After activation of the remote
SL
slave mode, „
" appears in the display. In addition, the slave group (GROUP)
selected and the remote channel (CH) are shown.
Testing remote flash mode
• Place the slave flash units in the desired positions for the shot. Use flash unit
mounting foot W-F127 to set up the slave flash unit.
• Wait for all of the flash units involved to become flash ready. Once the slave
flash units are flash ready, the AF measuring beam
• Press the manual firing button
test flash. The slave flash units will respond in succession, according to slave
group, with a test flash. If a slave unit fails to fire a test flash, check the set-
tings for remote channel and slave group. Correct the position of the slave
flash unit so that it is able to receive light from the master flash unit.
The flash mode is transmitted automatically by master or controller.
When the flash unit functions as master in the cordless remote system,
the activation of the modelling light also activates the modelling light of
slave flash units
will blink.
on the master or controller flash unit to fire a
79