Preliminary Operations - Master ACD 137 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
Refer to the "CONTROL PANEL" paragraph for
en
the operating modes.
it
►►2.1. REFRIGERANT CIRCUIT
de
The refrigerant gas used in these units is
R1234yf. The refrigerant circuit is built in com-
es
pliance with current standards.
fr
nl
Flammable material hazard.
pt
This unit is hermetically sealed and contains
fluorinated gas R1234yf GWP (R1234yf) = 4.
da
fi
no
►►►3. PRELIMINARY OPERATIONS
sv
pl
►►3.1. REMOVAL OF THE PACKAG-
ru
ING AND ASSEMBLY
(FIG. 3)
cs
Remove the packaging taking care not to dam-
hu
age the unit. Dispose of the packaging products
(wood, plastic, cardboard), taking them to the
sl
specialised collection or recycling centres (fol-
low the local regulations in force).
tr
CAUTION: Assemble the appliance, with the
hr
adequate air outlet (1 or 2-way outlet), handles,
wheels, cord reel and all the relevant nuts and
lt
bolts, before operating it.
lv
NOTE: Correct operation requires the appropri-
ate air outlet to be installed, according to the ac-
et
tual requirements.
ro
sk
►►3.2. INSPECTION
bg
All units are factory assembled and wired
(except for certain components). Upon receiving
uk
the unit, it must be immediately and thoroughly
inspected, checking that it has not been dam-
bs
aged during transport or that no parts are miss-
el
ing.
zh
Before use, specifically check for any dents
on the external metal panels, including those in
the tank compartment. Also check that the ca-
ble, plug and relevant insulation are intact. Oth-
erwise, it is FORBIDDEN to connect and start
the unit, which must be sent to an authorised
service centre.
►►3.3. OPERATING PRINCIPLES
CAUTION: To ensure correct operation of
the appliance, it is recommended to operate
the unit within the limits shown on the tech-
nical data table.
►►3.4. POSITIONING
Set up the appliance to ensure an adequate air
flow.
CAUTION: Make sure that the appliance is
placed in such a way so as to prevent contact
with water.
►►3.5. SERVICE AREA
The hot air expelled by the fan must not be ob-
structed. Avoid recirculation phenomena of the
air expelled and drawn by the appliance so as
to prevent compromising the performance of the
unit or even interrupting normal operation.
CAUTION: The equipment must not be
placed in cramped environments, which do not
allow adequate distribution of the air from the
dedicated inlets and outlets in the room.
CAUTION: Do not place or hang objects on
the front panel, it may cause damage to the unit.
►►3.6. GENERAL INFORMATION
CAUTION: Disconnect the power plug from
the socket before carrying out any maintenance
operation on the electrical part.
CAUTION: Check that the supply voltage
corresponds to the unit's operating data (volt-
age and frequency) shown on the data plate on
the dehumidifier. The appliance is fitted with a
power cable for correct operation.
CAUTION: The earthing connection is man-
datory.
►►►4. START-UP
►►4.1. PRELIMINARY CHECKS
CAUTION: Check that the power cord is
properly connected.

Publicidad

Tabla de contenido
loading

Tabla de contenido