6.2
Example circuit
EDK94MH594 DE/EN/FR/ES/IT 3.0
E94xMxExxxx
9400 Multi Drive servo axis module
F1 ... F2
Fuses, UL−certified types: 170M1761 or 170M1741, max. 315 A
"
HF−shield termination through large−surface connection to functional earth
EYF...
System cable for resolver feedback
RFR
Controller enable
R
Resolver
Y
Motor holding brake (connected to optional motor brake control)
Speed setpoint selection via analog input 1 (−10 ... 0 ... +10 V)
Voltage source for the motor holding brake
24 V voltage source for the digital inputs according to IEC 61131−2
24 V voltage source for the control electronics
l
Wiring the device
Example circuit
6
SSP94PSP6MD
67