Connect Wiring - Bosch DAH93 Instrucciones De Instalación

Ocultar thumbs Ver también para DAH93:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Connect Wiring

WARNING:
Use only spring type wire nuts (included) to make electrical
connections. Replacement wire nuts must be rated for a
minimum of (2) #18ga wires and a maximum of 4 #14ga
wires, UL &
CSA rated to 600V and 302º F/ 150º C.
Request #189692 when ordering from BSH.
For Internal Blower Use:
See Figure 1 or 2, page 3.
1. Remove electrical knockout behind J box and
install 1/2" conduit connectors.
2. Run 120V AC 60Hz, 15A supply wires through 1/2"
conduit to hood electrical knockout behind J box
cover.
3. Connect blower cord wires to house wiring through
electrical knockouts. Use wire nuts supplied (white
to white, black to black, green to green).
4. Connect blower cord at white connector behind
connector access panel (if not already connected).
Verify that connector is locked in place.
For Remote Blower Use:
See Figure 3, page 3.
1. Remove 2 hood electrical knockouts and install
1/2" conduit connectors.
2. Run black, white and green supply wires through
1/2" conduit to hood electrical knockout behind
J box.
3. Connect power supply wires to hood wires behind
J box (white to white, black to black, green to
green). Use wire nuts supplied.
4. Run 5 wires (#14 AWG) in 1/2" conduit from the
remote blower to the electrical knockout behind
the remote wire cover.
5. Connect remote blower wiring to "pigtail" wires
behind remote wire cover with wire nuts supplied
(black to brown, white to white, red to red and blue
to blue). See Figure 6.
6. Connect other end of "pigtail" at white connector.
Verify that connector is locked in place.
7. Reassemble Hood
Reattach the following:
1. Connector access panel (internal blower only)
2. J box
3. Remote wire cover (remote blower use only)
4. Back filter rail
5. Filters
Installation
Accessories
The following accessories are available from your Bosch
dealer or through Bosch Service: 800-944-2904. Please
reference the model number when requesting these items.
Accessory
6" Duct Covers
Biscuit
Black
Stainless Steel
White
12" Duct Covers
Biscuit
Black
Stainless Steel
White
Recirculation Kit
Biscuit
Black
Stainless Steel
White
Charcoal Filter
3 1/4 x 10Transition
Blowers*
Integral Blower, 400 CFM
Integral Blower, 600 CFM
Remote Blower, 600 CFM
Remote Blower, 1000 CFM
*for use with DAH95 models only
Figure 6 - Remote Blower Pigtail Assembly
M
5
Model #
30"
DCZ7607UC
DCZ7606UC
DCZ7605UC
DCZ7602UC
30"
DCZ7207UC
DCZ7206UC
DCZ7205UC
DCZ7202UC
30"
DRZ7007UC
DRZ7006UC
DRZ7005UC
DRZ7002UC
DHZ7960UC
DHZ3410UC
DHG4001UC
DHG6001UC
DHG6003UC
DHG1003UC
( PROVIDED W/HOOD )
GND
L1
N
BLACK
WHITE
BLACK
WHITE
RED
BLUE
GND
36"
N/A
DCZ9666UC
DCZ9665UC
DCZ9662UC
36"
N/A
DCZ9266UC
DCZ9265UC
DCZ9262UC
36"
N/A
DRZ9066UC
DRZ9065UC
DRZ9062UC

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dah94Dah95

Tabla de contenido