VC 6 L MC
–
When performing maintenance or repair work, all
contaminated items that cannot be cleaned sufficiently
must be disposed of. Use non-transparent sacks in
accordance with the applicable regulations to dispose of
this waste.
–
The outside of the device must be thoroughly cleaned and
freed of any hazardous substances. Alternatively, a sealed
coating can be applied before the device is removed from
the hazardous area.
–
During transport or maintenance of the device, the intake
opening must be sealed using the plug.
–
Danger of harmful dust. Always wear disposable clothing
and masks (P2 or higher) during maintenance work (e.g.
filter replacement).
–
On a device of category M, the outside of the equipment
must be decontaminated using a vacuum cleaner and
wiped down or covered in a sealing agent before it is
removed from the hazardous area. Once removed from the
hazardous area, all items of the device are deemed to be
contaminated. Suitable measures must be implemented to
prevent the spread of dust.
Cleaning
NOTE
Do not use cleaning agents containing silicone for cleaning.
–
No external assistance is required for the execution of
basic maintenance and cleaning.
–
The outside of the device and the inside of the container
must be cleaned at regular intervals with a damp cloth.
Filter cleaning system (Figure L)
The device is equipped with a semi-automatic filter cleaning
system. It cleans the filter and restores the suction power.
Switch on the device (1) to use the filter cleaning system.
Insert the nozzle pipe in the opening of the device (2) to
close it for air flow and to generate the maximum vacuum
in the dust container.
Press the filter cleaning button three times to clean the filter.
Manual filter cleaning (Figure M)
If the filter is soiled, rinse it in cold water (1) and allow it to dry
(2). Install the filter again once it has dried.
Changing the filter (Figure N)
After an extended period of use, the filter must be replaced by
a new one. If the filter is heavily soiled or clogged, manually
cleaning must be carried out as semi-automatic filter cleaning
will not be sufficient to clean the filter.
To remove the filter, loosen the screw (1) and remove the
parts (2).
Install the filter in the reverse order of removal. Make sure that
the screws are not overtightened.
Repairs
Have repairs carried out by an authorised customer service
centre only.
Spare parts and accessories
Other accessories can be found in the manufacturer's cata-
logues.
Exploded drawings and sparepart lists can be found on our
homepage: www.flex-tools.com
Disposal information
WARNING!
Render redundant power tools unusable by removing the
power cord.
EU countries only
Do not throw electric power tools into the household
waste!
In accordance with the European Directive 2012/19/
EU on Waste Electrical and Electronic Equipment and
transposition into national law used electric power tools must
be collected separately and recycled in an environmentally
friendly manner.
NOTE
Please ask your dealer about disposal options!
-Declaration of Conformity
We hereby declare that the product described on page 6 corre-
sponds with the following standards or normative documents:
EN 60335-1, EN 60335-2-69, EN 55014-1, EN 55014-2, EN
62233, EN 61000-3-2, EN 61000-3-3 in accordance with the
provisions of the directives 2014/30/EU, 2006/42/EC,
2011/65/EU.
Responsible for technical documents:
FLEX-Elektrowerkzeuge GmbH, R & D
Bahnhofstrasse 15, D-71711 Steinheim/Murr
04.11.2019
FLEX-Elektrowerkzeuge GmbH
Bahnhofstrasse 15, D-71711 Steinheim/Murr
15