Example :
The I welding current is set to a 100A and % (I_cold) = 50%, thus a Cold current of = 50% x 100A = 50A. F(Hz) is set to 10Hz, the signal period
will be 1/10Hz = 100ms.
Every 100ms, a 100A pulse then a 50A pulse will succeeed each other.
The choice of frequency
-
If welding with TIG electrodes, then F(Hz) synchronised to the gesture,
-
If thin plate without TIG electrodes (< 8/10 mm), F(Hz) >> 10Hz
-
If special metal requiring a welding pool sweep for degasing, then F(Hz) >> 100Hz
• Tack weld feature SPOT
SELECT STRIKING MODE
HF TIG: High Frequency start without contact
TIG LIFT : Contact start (for environments sensitive to HF disturbances).
Touch
Switch
Pré Gaz 0.5s
COMPATIBLE TORCHES
TIG 300 DC
TORCHES AND TRIGGER MODES
For the 1 button torch, the button is called «main button».
For the 2 buttons torch, the first button is called «main button» and the second button is called «secondary button».
2T MODE
t
Main button
T1
TIG 220 DC / 300 DC
TIG SPOT
The grey areas are not useful for this mode.
Lift
1- Touch the work-piece with the electrode
2- Press the trigger on the torch
3- Pull back the torch to lift the electrode.
<1s
L
DB
P
t
T2
MADE IN FRANCE
A
A
MEM
V
V
PROG
S / Hz
%
10
s
20
s
0
s
L
DB
P
T1 - The main button is pressed, the welding cycle starts (PreGas,
I_Start, UpSlope and welding).
T2 - The main button is released, the welding cycle is stopped (DownS-
lope, I_Stop, PostGas).
For the double button torch and in 2T mode only, the secondary but-
ton works like the main button.
EN
L
DB
P
21