Recommended Combinations - GYS TIG 220 DC Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
t
Main button
T1
t
4T MODE
Main button
T1
Main button
T1
T2
Main button
T1
T2
4T MODE log
Main button
T1
T2
or
Main button
Secondary button
T1
T2
or
Secondary button
For this mode it may be convenient to use the dual button torch option or dual button with potentiometer. The «up» command keeps the same func-
tion as the single button or trigger torch. The «down» button can, when pressed, switch to the cold current. The potentiometer of the torch, where
available, allows control of the welding current from 50% to 100% of the value displayed.

RECOMMENDED COMBINATIONS

Process
TIG DC
MMA
0.3 - 3 mm
DC
2.4 - 6 mm
4 - 8 mm
6.8 - 8.8 mm
9 - 12 mm
ELECTRODE GRINDING
To optimise the welding process, it is recommended to grind the electrode prior to welding as described below:
22
t
TIG 220 DC / 300 DC
t
T2
T2
t
t
t
t
T3
T3
<0.5s
<0.5s
<0.5s
<0.5s
t
t
Type
HF
STD
PULSE
SPOT
STD
PULSE
Current (A)
5 - 75
60 - 150
100 - 200
170 - 250
225 - 300
d
T1 - The main button is pressed, the cycle starts at PreGas and stops in
the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope and in
welding.
T3 - The main button is pressed, the cycle switches to DownSlope and
stops in I_Stop.
T4 - The main button is released, the cycle ends with PostGas.
Nb : for torches, double button and double button with potentiometer
=> command « up/welding current » and active potentiometer,
command «low » inactive.
T4
T4
>0.5s
T1 - The main button is pressed, the cycle starts at PreGas and stops in
>0.5s
the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope and in
welding.
t
LOG : this mode is used during welding :
- A brief press of the main button (<0.5s), the current switches from I
t
welding current to I cold and vice versa.
- the secondary button is kept pressed, the weldin current switches
T4
T3
from I welding current to I cold
- the secondary button is kept released, the current switched from I
T4
T3
cold to I welding current.
T3 – A long press on the main button (>0.5s), the cycle swicthes to
DownSlope and stops in the I_Stop phase.
T4 - The main button is released, the cycle finishes with PostGas.
Lift
-
Electrode (mm)
1
1.6
2
2.4
3.2
L = 3 x d for a low current.
L = 3 x d for a high current
L
Argon flow rate (L/
Shroud (mm)
min)
6.5
6 - 7
8
6 - 7
9.5
7 - 8
11
8 - 9
12.5
9 - 10
EN