Type C33X (Concentric Flue System) - Daikin D2CNL024A1AA Manual De Instalación

Caldera de condensación de montaje en pared
Ocultar thumbs Ver también para D2CNL024A1AA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Equivalent length of options
90° elbow 60/100 mm
45° elbow 60/100 mm
30° elbow 60/100 mm
90° elbow 80/125 mm
45° elbow 80/125 mm
30° elbow 80/125 mm
60/100 flue length can be increased up to 17.9  metres by
adjusting the parameter. Refer to servicing instructions for this
operation.
Subtract equivalent length value of bends from the allowable flue
length value.
Flue length determination
Flue duct length (L) is measured from lip of the elbow to end of the
flue terminal.
L
L
Flue duct length
a
Distance of outer lip of terminal to outer wall, a≤50 mm
Note: Flue ducts are inserted 45 mm into elbows and extensions.

Type C33x (concentric flue system)

The boiler draws combustion air from the outside and expels flue
gas to the outside through a concentric coaxial pipe via the roof.
The terminal outlets from separate combustion and air supply
circuits shall fit inside a square of 50 cm and the distance between
the planes of the two orifices shall be less than 50 cm.
D2CNL024A1AA
Wall-mounted condensing boiler
3P469346-12P – 2020.07
1.5 m
1.0 m
1.0 m
1.5 m
1.0 m
1.0 m
a
a
c
d
c
d
f
a
Roof terminal 60/100
b
Tile roof outlet kit
Optional:
c
45° elbow 60/100
d
Extension 60/100 mm
e
Flat roof outlet kit
f
90° elbow 60/100
g
45° elbow 60/100
h
30° elbow 60/100
i
Extension 60/100
L = 500-1000 mm
Allowable flue length for C33x
Concentric 60/100 mm
Concentric 80/125 mm
Equivalent length of options
90° elbow 60/100 mm
45° elbow 60/100 mm
30° elbow 60/100 mm
90° elbow 80/125 mm
45° elbow 80/125 mm
30° elbow 80/125 mm
60/100 Vertical flue length can be increased up to 19.2  metres
by adjusting the parameter. Refer to servicing instructions for
this operation.
Subtract equivalent length value of bends from the allowable flue
length value.
80/125 mm flue system
To increase the maximum allowable flue duct length, 80/125  mm
concentric flue ducts can be used instead of 60/100  mm. In this
case, C13x and C33x flue systems should start with a 60/100 to
80/125 adapter coupled to the flue outlet.
4 Installation
b
e
g
h
i
L
12.5 m
42.8 m
1.5 m
1.0 m
1.0 m
1.5 m
1.0 m
1.0 m
Installation Manual
17

Publicidad

Tabla de contenido
loading

Tabla de contenido