Safety

Important Safety Instructions

SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation, operation, and maintenance of the product.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential
for personal injury!
indicates a hazard which, if not avoided, will
result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE addresses practices not related to
personal injury.
Carefully read and follow all safety instructions in this
manual and on pump .
Keep safety labels in good condition. Replace missing or
damaged safety labels.
California Proposition 65 Warning
This product and related accessories contain
chemicals known to the State of California to cause
cancer, birth defects or other reproductive harm.
1. Drain all water from system before servicing.
2. Periodically inspect reservoir, pump, and system
components. Keep free of debris and foreign objects.
Perform routine maintenance as required.
3. When installing an electrically driven pump, follow
all electrical and safety codes that apply.
4. Make certain power source conforms to requirements
of your equipment.
5. Protect electrical cord from sharp objects, hot surfaces,
oil, and chemicals. Avoid kinking cord. Replace or
repair damaged or worn cords immediately.
6. Personal Safety:
a. Wear safety glasses at all times when working with pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment.
c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, master
switches, and by removing starter keys.
Risk of electric shock . Can shock, burn or
kill. If your basement has water or moisture on floor, do
not walk on wet area until all power has been turned
off. If shut-off box is in basement, call electric company
to shut-off service to house, or call your local fire
department for instructions. Failure to follow this warning
can result in fatal electrical shock.
When pump is plugged in, do not handle pump, cord, or
plug with wet hands or when standing on a wet or damp
surface or in water. Unplug pump before servicing it or
doing any maintenance on it.
Risk of fire and explosion . Can cause severe
injury, property damage or death. Do not use this pump
to pump flammable or explosive liquids. Use pump only
For parts or assistance, call Flotec Customer Service at
with liquids compatible with pump component materials.
Do not use pump in explosive atmospheres.
Risk of flooding . Can cause personal injury
and/or property damage. If for any reason property
damage or personal injury can result from an inoperative
or leaking pump, an auxiliary switch backup system
and/or an alarm should be installed with pump.
Installation
Pump must be level!
Pump can also be installed
on wall or floor. Allow at least
6-1/2" vertical clearance to
allow tank removal.
Mount pump on side of furnace (or on floor or
1
wall).
Risk of electric shock and carbon monoxide
poisoning . Can shock, burn or kill. When mounting
the pump on the side of the furnace, make sure that the
mounting holes clear the heat exchanger and all wiring.
The mounting screw for the pump should touch only the
pump reservoir flange and the exterior sheet metal on
the furnace. If in doubt or if this is confusing, consult a
qualified HVAC serviceman or the furnace manufacturer.
AC Unit
Condensate
Furnace
Drain
Condensate
Drain
Plastic
Tubing
Run plastic tubing as shown into pump's drain inlet
2
hole(s).
800-365-6832
From A.C.
Unit
Gas
Condensing
Furnace
Mount Pump
below all Heater
and A.C. Drains
5490 0906
A t
l e
a s
t 6
- 1
/ 2
"
Cut tubing at an angle
so that bottom of
reservoir doesn't close it.
Be sure tubing does not
interfere with float.
1-1
" above
1 2
bottom of
reservoir
5491 0906