Pentair OMNIFILTER CBF1 Instrucciones De Instalación página 7

Sistema de filtración de agua potable para debajo del fregadero
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CBF3 PERFORMANCE DATA
Important Notice: Read performance data and compare the
capabilities of this system with your actual water treatment
requirements. It is recommended that the supply water be tested,
before installing a water treatment system, to determine your
water treatment needs.
CBF3 System with CB3 Filter Cartridge installed
This system has been tested according to NSF/ANSI 42 and 53 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
exiting the system, as specified in NSF/ANSI 42 and 53.
Influent Challenge
Substance
Concentration
Standard 42
Chlorine
2.0 mg/L ± 10%
Standard 53
Minimum 50,000
Cysts**
Microsphere/L
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
Mercury
0.006 ± 10%
(pH 6.5)
Mercury
0.006 ± 10%
(pH 8.5)
VOC
0.300 mg/L ± 10%
MTBE
0.015 ± 20%
**NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia
by mechanical means
CBF3 Test Conditions
Flow Rate
CB3 cartridge
Filter Capacity
CB3 cartridge
Inlet Pressure
= 60 psi (4.1 bar)
pH
= 7.5±1
Temperature
= 68°F ± 5°F (20°C ± 2.5°C)
Testing was performed under standard laboratory conditions;
actual performance may vary.
Operating Requirements
Pressure = 30-125 psi
Temperature
= 40-100°F
Turbidity = 5 NTU Max.
EPA Est. No. 090375-Mex-001
Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Note: Filter must be maintained according to manufacturer' s
recommendations, including replacement of filter cartridges.
The contaminants or other substances reduced by this water
treatment device are not necessarily in your water.
Maximum
Reduction
Average
Permissible
Requirements
Reduction
Product Water
≥50%
99.95%
>99.99%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.015 mg/L
0.005 mg/L
0.5 gpm
400 gallons
Reduction claims for organic chemicals
included by surrogate testing
Substance
alachlor
atrazine
benzene
carbofuran
carbon tetrachloride
chlorobenzene
chloropicrin
2,4-D
dibromochloropropane (DBCP)
o-dichlorobenzene
p-dichlorobenzene
96.4%
1,2-dichloroethane
1,1-dichloroethylene
cis-1,2-dichloroethylene
trans-1,2-dichloroethylene
99.2%
1,2-dichloropropane
98.4%
cis-1,3-dichloropropylene
96.7%
dinoseb
endrin
96.5%
ethylbenzene
99.7%
ethylene dibromide (EDB)
90.1%
haloacetonitriles (HAN):
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
haloketones (HK):
1,1-dichloro-2-propanone
1,1,1-trichloro-2-propanone
heptachlor
heptachlor epoxide
hexachlorobutadiene
hexachlorocyclopentadiene
lindane
methoxychlor
pentachlorophenol
simazine
styrene
1,1,2,2-tetrachloroethane
tetrachloroethylene
toluene
2,4,5-TP (silvex)
tribromoacetic acid
1,2,4-trichlorobenzene
1,1,1-trichloroethane
1,1,2-trichloroethane
trichloroethylene
trihalomethanes (includes):
chloroform (surrogate chemical)
bromoform
bromodichloromethane
chlorodibromomethane
xylenes (total)
Maximum permissible
Influent challenge
product water
concentration (mg/L)
concentration mg/L
0.05
0.001
0.1
0.003
0.081
0.001
0.19
0.01
0.078
0.0018
0.077
0.001
0.015
0.0002
0.11
0.0017
0.052
0.00002
0.08
0.001
0.04
0.001
0.088
0.0048
0.083
0.001
0.17
0.0005
0.086
0.001
0.08
0.001
0.079
0.001
0.17
0.0002
0.053
0.00059
0.088
0.001
0.044
0.00002
0.022
0.0005
0.024
0.0006
0.0096
0.0002
0.015
0.0003
0.0072
0.0001
0.0082
0.0003
0.025
0.00001
0.0107
0.0002
0.044
0.001
0.06
0.000002
0.055
0.00001
0.05
0.0001
0.096
0.001
0.12
0.004
0.15
0.0005
0.081
0.001
0.081
0.001
0.078
0.001
0.27
0.0016
0.042
0.001
0.16
0.0005
0.084
0.0046
0.15
0.0005
0.18
0.001
0.3
0.015
0.07
0.001
• 7 •

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Omnifilter cbf3

Tabla de contenido