Technical data

Rated data

4.2
Rated data
Mains
3/PE AC
3/PE AC
3/PE AC
E94AZRP0084
E94AZRP0294
E94AZRP0294
 Temperature in the control cabinet
2)
For i700 mounting: mains connection at the bottom, output at the top
E94AZRP0084
E94AZRP0294
40
Voltage
U
[V]
Lrated
230
400
500
Voltage
[V]
230/400/500
230/400/500
2)
400/500
Power loss
P
[W]
loss
20
50
Voltage range
U
[V]
Lrated
180 − 0 % ... 264 + 0 %
320 − 0 % ... 440 + 0 %
400 − 0 % ... 550 + 0 %
Freq.
Current [A]
 max. +45° C
[Hz]
50/60
8/8/8
50/60
29/29/29
50/60
24.5/24.5
Inductance
L [mH]
˘
˘
l
Frequency range
f [Hz]
45 − 0 % ... 65 + 0 %
45 − 0 % ... 65 + 0 %
45 − 0 % ... 65 + 0 %
Current [A]
Number
of phases
 max. +55° C
6/6/6
3
21.8/21.8/21.8
3
15.3/15.3
3
Voltage drop
DU [V]
˘
˘
EDK94AZRP DE/EN/FR/ES/IT 7.0