Rated Data - Lenze E94AZHY0026 Instrucciones Para El Montaje

Control de freno de motor
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Rated data

Input data
Type
E94AZHY0026

Temperature in the control cabinet
Output data
Type
E94AZHY0026

Temperature in the control cabinet
Area
Input voltage
Output voltage
Brake current
Cable protection
Control input
Control voltage
Control current
Protective function
Max. connectable cable
cross−section
Maximum cable length
EDK94AZHY26 DE/EN/FR/ES/IT 1.2
Voltage
Frequency
[V]
[Hz]
400/500
50/60
Voltage
Frequency
[V]
[Hz]
180/225
0 (DC)
Values
AC 400 V (320 ... 550 V), 45 ... 65 Hz
DC 180 V
With mains voltage of AC 400 V
0.1 ... 0.61 A
Recommendation: 5 A, tripping characteristic "B" or "C"
Internal
2
2.5 mm
AWG 12
150 m
l
Technical data
Rated data
Current [A]
max. +45 °C
max. +55 °C


0.61/0.61
0.61/0.61
Current [A]
max. +45 °C
max. +55 °C


0.61/0.61
0.61/0.61
2
Number
of
phases
1
Number
of
phases
1
33