In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and safety) can be displayed. One
segment of the display is linked to each input. In the event of failure it switches on according to the following scheme.
The control unit checks the correct operation of the safety devices. In case of failure, the following messages may appear on the
display:
Error, check photocells at PHOT O input.
ERR1
Error, check photocells at PHOT C input.
ERR2
Error, ENCODER/ check fuse F3
ERR3
Error, TRIAC
ERR4
F1
Protection fuse of transformer
F2
Output protection fuse of accessories and signals
F3
Output protection fuse for motor and blinker
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal
and the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a
specialised company.
TECHNICAL DATA
Power supply
Output supply
Power maximum motor
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported
It is provided with "Single fault test" function, in compliance with the Machinery Directive 98/37/EC.
Diagnostics
SWO
SWC
P.P.
PED
OPEN
PHOT 0
STOP
PHOT C
DAS
Error messages
Fuses
Waste Disposal
230 Vac 50/60 Hz
1 motor 230Vac
1000 W
24Vdc 500mA max.
IP54
-20°C / +70°C
CP.BULL-RI / MATRIX: built in 433,92 MHz confgurabile (rolling-code or
programmable + rolling-code)
CP.BULL / MATRIX-RE: removable connector for radio receiver
64
CLOSE
15