Servicing the Battery
If it is necessary to service the battery, proceed as follows:
1. Remove "Control Panel" access cover.
. Set generator's system switch to OFF.
3. Remove 15 Amp fuse from control panel.
4. Service or replace battery as required.
NOTE: Replace ONLY with same type battery as described in
Battery in Installation.
5. Connect red battery cable to battery positive terminal
(indicated by POSITIVE, POS, or (+)).
6. Connect negative battery cable to negative battery
terminal (indicated by NEGATIVE, NEG, or (-).
7. Ensure hardware on both positive and negative battery
terminals is secure.
8. Reinstall 15 Amp fuse in control panel.
9. Set generator's system switch to AUTO.
10. Reset exercise timer. See Setting Exercise Timer.
11. Install "Control Panel" access cover.
To Clean the Generator
notice
Improper treatment of generator can damage it and
shorten its life.
DO NOT expose generator to excessive moisture, dust,
dirt, or corrosive vapors.
DO NOT insert any objects through cooling slots.
• Use a damp cloth to wipe exterior surfaces clean.
• Use a soft, bristle brush to loosen caked on dirt,
oil, etc.
• Use a vacuum cleaner to pick up loose dirt and debris.
• Use low pressure air (not to exceed 5 psi) to blow
away dirt. Inspect cooling air slots and openings on
the generator. These openings must be kept clean
and unobstructed.

When Calling For Assistance

You must have the following information at hand if it is
necessary to contact a local service center regarding service
or repair of this unit:
1. Obtain the unit Model Number and Serial Number from
the unit data decal. See Controls.
. Obtain the engine Model/Type/Code numbers from the
engine label. See Controls. Please note that the model
number may vary slightly from that presented herein.

Storage

The Rheem / Ruud Residential Generator System is designed
for long term service as a backup generator. As such, there
is no need to take any storage precautions. However, if
it becomes necessary to take the system out of service
for an extended period, call Rheem Technical Services at
(877) 369-9400, between 8:00 AM and 5:00 PM CT for
specific recommendations. Refer to the engine operator's
manual for further information.