MARK HOLES
Select the vent option that your installation will
require and proceed to that section:
A
Outside top exhaust
(Vertical duct–3-1/4" x 10" Rectangular)
Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hood mounting
screws (4)
10
(24 hood)
3 4
13
(30 hood)
3 4
16
(36 hood)
3 4
Cabinet front
Cabinet Bottom
5
1 4
Vertical duct
3
3 4
access hole
1 2
Wood shims
Center
(recessed-bottom
cabinets only–shims
must be a minimum
of 3/8 thick and cut
to fit the width of
the inner recessed
cabinet bottom)
Outside top exhaust
B
(Vertical duct–7" Round)
Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hood mounting screws (4)
10
(24 hood)
3 4
13
(30 hood)
3 4
16
(36 hood)
3 4
Cabinet front
Cabinet
bottom
Access
hole for 7
round duct
Wood shims
(recessed-
bottom cabinets only–shims
must be a minimum of 3/8
thick and cut to fit the width
of the inner recessed cabinet
bottom)
49-80589-7
Installation Instructions
10
(24 hood)
3 4
13
(30 hood)
3 4
16
(36 hood)
3 4
7
3 4
5
1 4
1
1 4
1
3 8
Electrical access hole
(in cabinet bottom)
line
10
(24 hood)
3 4
13
(30 hood)
3 4
16
(36 hood)
3 4
7
3 4
8 DIA.
1
1 4
HOLE
5
3 4
1
3 8
Electrical access
hole
Center
(in cabinet bottom)
line
Outside rear exhaust
C
(Horizontal duct–3-1/4" x 10" Rectangular)
Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Wood shims
(recessed-bottom cabinets only–shims must be
a minimum of 3/8 thick and cut to fit the width
of the inner recessed cabinet bottom)
Cabinet
bottom
10
13
16
9
5 8
Hood mounting
screws (4)
Recirculating (non-vented ductless–
D
JN327, JN328 and RN328, and optional on
JV247, JV248, JV347, JV348, JV367 and
AV447 models only)
• Use the hood as a template and mark the
locations on the cabinet for the electrical
wiring and keyhole screw slots.
• Since the hood is to be recirculated (not to
be vented outside), do not cut out any vent
openings in the wall or cabinet bottom.
12
CUT HOLES
Cut holes at marked locations for duct and
electrical wiring. For the vertical duct, cut out
you can move the duct freely when installing
the hood. It may also ease installation by
9
5 8
13
RUN WIRES
Run the electrical wires through the wall or
cabinet according to National Electrical Code
and applicable local codes.
NOTE: DO NOT turn the power on until
installation is complete.
Cabinet front
1 2
Horizontal duct
3
3 4
access hole
5
5
1 4
1 4
7
3 4
(24 hood)
3 4
10
(24 hood)
3 4
(30 hood)
3 4
13
(30 hood)
3 4
(36 hood)
3 4
16
(36 hood)
3 4
Electrical access
Center line
hole
1
1 4
(in wall)
13