Troubleshooting tips ... Before you call for service
Save time and money! Review the charts on the following pages first and you may not need to call for service.
Problem
Fan/Light does not operate
Loud or abnormal airflow
noise
Fan fails to circulate
air or moves air slower
than normal and/or fan is
making loud or abnormal
airflow noise
Early light failure
16
Possible Cause
A house fuse may be blown or
a circuit breaker tripped.
Wrong duct size used in
installation.
Obstructions in duct work.
Damper blade on wall or roof
cap may not be open.
Metal grease filter and charcoal
filter (if present) may be dirty.
Insufficient makeup
(replacement) air
Light wattage is too high.
What To Do
Replace fuse or reset circuit breaker.
Using smaller duct pipe will cause reduced venting.
Minimize the duct run length and number of transitions
and elbows. GE Appliances service technicians cannot
correct this issue if installed improperly.
Make sure nothing is blocking the vent. Make sure your
wall or roof cap has a blade or door.
Make sure damper swings freely. Damper blades may flip
over and will not fully open when this happens. Adjust to
original position.
Clean the metal grease filter and replace charcoal filter (if
present). See Care and Cleaning of the Vent Hood.
Sufficient makeup (replacement) air is required for
exhausting appliances to operate to rating. Check with
local building codes, which may require or strongly
advise the use of makeup air. Visit GEAppliances.com for
available makeup air solutions.
Replace with correct wattage.