The cover is designed for both applications (note that in the two
cases the release device is located in different positions). There
are also two tabs for fixing the power cable to the clear light
fixture (Fig. 19).
Figs.17-18 also show the recommended layout for routing and
fixing the cables in the card support.
KEY TO CABLES
Flashing light
External courtesy light
OPEN button on cover
Low-voltage connections
550 Slave motor
230V~ power supply
550 I motor

7. MANUAL OPERATION

The operator 550 is equipped with an emergency release
device that can be operated from inside the garage. On
request, a lock can be fitted to the door panel which allows the
release device to be operated also from outside the garage.
If the door has to be operated manually due to a power failure
or a malfunction of the automation system, operate the release
device as follows:
- From inside (Fig. 20)
Insert the hex wrench provided and turn clockwise about half a
turn until the stop is reached.
Warning:depending on the type of installation, the release
device may be on the right (A) or left (B).
Fig. 20
- From outside (Fig.21)
1) Open the safety door and insert the wrench.
2) Turn anticlockwise as far as possible and remove the lock unit.
3) Insert the hex wrench provided and turn anticlockwise about
half a turn until the stop is reached.
Fig. 17
Fig.21
8. RETURNING TO NORMAL OPERATION
To prevent an accidental movement from activating the door
during the operation, disconnect the power supply from the
system before locking the operator again.
- From inside (Fig.20)
Insert the hex wrench provided and turn anticlockwise about
half a turn until the stop is reached.
Note:depending on the type of installation, the release device
may be on the right (A) or the left (B).
- From outside (Fig.21)
1) Insert the hex wrench provided and turn clockwise about half
a turn until the stop is reached.
Fig. 18
2) Remove the hex wrench and insert the lock unit.
3) Turn the wrench clockwise so that it can be removed; close
the safety door again.
9 MAINTENANCE
Carry out the following operations at least every six months:
•Check that the motor torque is set correctly.
•Check the door's rollers and sliding guides; clean and
lubricate if necessary.
• Check the efficiency of the release system.
•Check the efficiency of the safety devices.
10 REPAIRS
For repairs contact authorised FAAC Service Centres.
Fig. 19
16
B
SBLOCCA/UNLOCK
DEBLOQUE/ENTRIEGELT
DESBLOQUEAR
BLOCCA/LOCK
BLOCCA/LOCK
BLOQUE/VERRIEGELT
BLOQUE/VERRIEGELT
BLOQUEAR
BLOQUEAR
DEBLOQUE/ENTRIEGELT
SBLOCCA/UNLOCK
DEBLOQUE/ENTRIEGELT
DESBLOQUEAR
ENGLISH
A
SBLOCCA/UNLOCK
DESBLOQUEAR
BLOCCA/LOCK
BLOQUE/VERRIEGELT
BLOQUEAR

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

550 mp

Tabla de contenido