9 STOVE OPERATION

9.1 STARTING THE STOVE
To start the stove hold the
Automatic stove ignition: the stove comes with an automatic device that starts the pellet stove without using other
or drying of certain materials used. This phenomenon will gradually disappear.
9.2 MODIFYING THE PARAMETERS
power supply.

9.3 SWITCHING OFF

To switch the stove off hold the
To start the stove again it's recommended to wait for the stove to cool down completely.
The stove should only be switched off following the procedure described above. Never switch the stove off by
unplugging it from the power supply.
9.4 OPERATION WITH ROOM THERMOSTAT
When the stove is controlled by an external thermostat (or timer thermostat), the installer must have set
output (that is, the stove attempts to maintain the desired temperature while minimising fuel consumption) when
reaching the set water temperature.
The stove switches on again automatically when the temperature falls below the value set on the external
thermostat (circuit closed).
The stove will go off automatically even in the case the water temperature keeps growing notwithstanding the modulation
mode. In this case the stove will ignite only if the difference between the selected and actual temperature is over 20°C.
9.5 OPERATION WITH ROOM PROBE ON THE STOVE
The stove can be switched on/off manually or in programmed mode.
the stove (that is, the stove attempts to maintain the desired temperature while minimising fuel consumption).
If the user has enabled the "Eco-mode" function under the power menu
modulating its output, switches off when reaching the set temperature, and switches on again when the
room temperature falls below the delta set in submenu "4" of the temperature menu
The desired room temperature can be set in submenu "1" of the temperature menu
Submenu "2" can be used to set the desired water outlet temperature (the best temperature for the heating
system in question should be suggested by the heating system installer).
9.6
OPERATION IN COMBINATION WITH A STORAGE TANK
whether the storage tank is with or without a coil inside.
The stove is controlled based on the temperature read by the probe in the storage tank.
When reaching the storage tank temperature set in the temperature menu
switches on again if the temperature falls below the delta set in submenu "4" of the temperature menu