Lenze E94ASHE Serie Instrucciones Para El Montaje página 93

Ocultar thumbs Ver también para E94ASHE Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Mains
Terminal X100
Connection with ring
cable lug for M10
Terminal data
Device size 8:
E94ASxE1724
E94ASxE2024
Device size 9:
E94ASxE2454
E94ASxE2924
E94ASxE3664
Motor temperature monitoring
Terminal X106
Terminal data
Flexible
With wire end
ferrule
Motor brake control (optional)
Terminal X107
Terminal data
Flexible
With wire end
ferrule
EDK94SH366 DE/EN/FR/ES/IT 3.1
Marking
Description
L1
Connection of the mains phases
L2
L3
Connection for the PE conductor on the supply side
SSP94KL801
Max. conductor cross-section
2
[mm
]
2 x 240
2 x 500 mcm
Labelling
Description
T1
Motor temperature monitoring with PTC element (type-A sensor,
switching performance according to EN 60947-8 for type-A tripping
T2
units) or thermostat (NC contact).
SSP94X6106
Max. conductor cross-section
2
[mm
]
2.5
Labelling
Description
Connection of the motor holding brake
BD1
+ (Lenze: WH)
BD2
- (Lenze: BN)
E94AZHY0101: 24 V DC, max. 5.0 A
Observe correct polarity!
+ / -
Supply voltage for the motor holding brake (18 ... 30 V DC)
Observe correct polarity!
SSP94X6107
Max. conductor cross-section
2
[mm
]
2.5
Wiring the device
Power terminals
Tightening torque
[AWG]
[Nm]
19
Tightening torque
[AWG]
[Nm]
12
0.5 ... 0.6
Tightening torque
[AWG]
[Nm]
12
0.5 ... 0.6
5
Screw drive
[lb-in]
168
WAF 16
Screw drive
[lb-in]
Slot
4.5 ... 6.2
0.6 x 3.5
Screw drive
[lb-in]
Slot
4.5 ... 6.2
0.6 x 3.5
93

Publicidad

Tabla de contenido
loading

Tabla de contenido