ENGLISH
OPERATING INSTRUCTIONS
TEMPERATURE
1. Insert K-type thermocouple into the VΩ
(observe polarity markings on thermocouple and meter), and rotate
function selector switch
2
NOTE: The meter defaults to Fahrenheit scale in this mode. To enter
Celsius scale, press the "SELECT" button
appropriate icon (either °F or °C ) appears on the display.
2. To measure temperature, make contact between the
thermocouple tip and the object being measured. When
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilize. The meter will auto-
range to display the measurement in the most appropriate range.
K-Type
Thermocouple
Remove thermocouple before switching meter to other
measurement functions.
The thermocouple included with the original purchase is
suitable for temperatures below 446°F / 230°C only.
To measure higher temperatures, a K-type thermocouple
with the appropriate measurement range should be used.
16
and COM
jacks
5
4
to the Temperature
setting.
once. Ensure that the
12
MAINTENANCE
BATTERY REPLACEMENT
When
indicator is displayed on LCD, batteries must be replaced.
1. Loosen screw on battery door.
2. Replace 3 x AAA batteries (note proper polarity).
3. Replace battery door and fasten securely with screw.
To avoid risk of electric shock, disconnect leads from any voltage
source before removing battery door.
To avoid risk of electric shock, do not operate meter while
battery door is removed.