Troubleshooting - Aircare EA1407 Guía De Uso Y Cuidado

Ocultar thumbs Ver también para EA1407:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting

Trouble
Digital display not
illuminated.
Fan not operating (digital
display is illuminated).
Fan running continuously.
Poor evaporation of water.
Neither bottle emptying.
Bottles continue to empty
after complete filling.
Left bottle not emptying.
Bottle empties completely
Refill display "F" is on
before bottles are empty.
"CF" message does not
appear even when wick is
dirty or humidifier
performance is clearly
reduced.
Display blinks or fan moves
slightly when humidifier is
plugged in.
Probable Cause
• No Power.
• Power button has not been
depressed.
• ROOM humidity level is not 3%
or more below SET humidity
level.
• Reservoir is empty.
• Float is obstructed.
• SET humidity level is
65%.
• ROOM humidity level
has not reached 1% or
more above SET
humidity level.
• CHECK FILTER (CF) message
flashing.
• Mineral buildup on filter (wick).
• Bottle cap plunger
missing post in bottom
of cabinet
• Dirty wicks.
• Air is entering water
bottle.
• Right bottle contains
water.
• This is normal for initial filling
• Unit is not set up on a
level surface. (Float
will not sense water at
the front of the
cabinet.)
• Loss of power or a
power failure has caused the
CF message to prematurely
reset.
Normal
13
Remedy
• Check 120 volt power source.
• Press power button once to
turn on.
• Raise SET humidity level if desired.
• Increase fan speed.
• Fill humidifier with water.
• Free float from obstruction.
• A SET humidity percentage of 65%
operates fan continuously. Adjust
SET level between 25% - 60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
• Change to a fresh new wick
NOTE: Local water varies from area
to area and under certain conditions
minerals will build up more rapidly in the
wick.
•Unplug unit for 1-2 minutes to reset
CF function
• Check orientation of bottles.
Reposition so that bottle cap
plunger (stem) is depressed by
post in bottom of cabinet.
• Change to fresh new wick
(HDC12).
•Check "Side-Fill Caps" and valve
assembly caps to ensure tightness.
• Check for leak in water bottle.
• Ensure gaskets for "Side Fill Caps"
are in place.
•The humidifier is designed so that
right bottle empties first.
• Ensure unit is level - Install caster
pads on front casters, as needed.
• Refill bottle for maximum
run time.
• Position unit level. (Some carpet padding
may allow unit to sit lower in the front than
rear with the additional weight of water
bottles in the front of the cabinet. Install
caster pads under front casters.
• Replace wick.
• No action required.