IMPORTANT: Water
damage may result if
condensation starts to form
on windows or walls.
Humidity SET point should
be lowered until
condensation no longer
forms. We recommend
room humidity levels do not
exceed 50%.
HUMIDISTAT
This unit has an humidistat located on the power cord. It
senses the percentage of humidity in the air and causes
the humidifier to cycle on and off to maintain the
selected humidity SET point. The fan will turn on if the
"ROOM" reading falls 3% below the SET
point and will continue to run the humidifier until
a reading of 1% above the SET point is achieved. The
fan will turn off until the ROOM reading falls 3% below
the SET point again.
NOTE: Be sure the humidistat located on the power cord
is at least two inches away from the wall, free from
obstruction and away from any hot air source.

CONTROLS AND OPERATION

Where you set your desired humidity levels depends on your personal comfort level,
outside temperature and inside temperature. A starting set point of 30% to 40%
ROOM humidity is recommended but there may be conditions that require a different
setting.
NOTE: If excessive condensation occurs, reduce fan to a lower speed setting.

DIGITAL DISPLAY

Press the power button once to
turn the unit on. Initially there is a
slight delay while the electronics
calibrate.Two bars (- -) appear
during this time. Once calibration
is complete a ROOM humidity
reading between 20% - 90% will
be displayed.
NOTE: The default settings at
initial startup are (LOW) F1 fan
speed and 65% SET humidity. After desired settings are selected by the user, they
remain as long as the unit remains plugged in and there is no power interruption.
When the unit is unplugged, the original default settings are reinstated.
*When Outdoor
Temperature is:
°F
° C
-20
-30°
-10°
-24°
-18°
10°
-12°
20°
-6°
30°
-1°
*Or above
7
Recommended
Indoor Relative
Humidity (RH)
is
15 - 20%
20 - 25%
25 - 30%
30 - 35%
35 - 40%
40 - 45%