BFT RIGEL 6 Instrucciones De Instalación página 48

Centralita universal para controlar uno o dos motores
Ocultar thumbs Ver también para RIGEL 6:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
Logic
Definition
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
Configuration of
EXPO2 output
on input-output
EXPO1
expansion board
Configuration of
EXPO2 output
on input-output
EXPO2
expansion board
TRAFFIC LIGHT
Traffic light pre-
flashing
PREFLASHING
TRAFFIC LIGHT
Steadily lit red light
RED LAMP
ALWAYS ON
*
Only active on FW > 1.12
CH logic= 0 - Control configured as Start E. Operation according to STEP-BY-STEP MOV. logic. External start for traffic light control.
CH logic= 1 - Control configured as Start I. Operation according to STEP-BY-STEP MOV. logic. Internal start for traffic light control.
CH logic= 2 - Control configured as Open.
The command causes the leaves to open.
CH logic= 3 - Control configured as Closed.
The command causes the leaves to close.
CH logic= 4 - Control configured as ped.
The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to STEP-BY-STEP. logic
Logica CH= 5- Control configured as STOp.
The command performs a STOp
CH logic= 6 - Control configured as AUx0. (**)
The control activates the AUx0 output
CH logic= 7 - Control configured as AUx1. (**)
The control activates the AUx1 output
CH logic= 8 -Control configured as AUx2. (**)
The control activates the AUx2 output
CH logic= 9 - Control configured as AUx3. (**)
The control activates the AUx3 output
CH logic= 10 - Control configured as ExpO1. (**)
The control activates the ExpO1 output
CH logic= 11 - Control configured as ExpO2. (**)
The control activates the ExpO2 output
(**) Active only if the output is configured as Monostable Radio Channel, Courtesy Light, Zone Light, Stair Light, Bistable Radio Channel or Timed Radio Channel.
48
- RIgEL 6
INSTALLATION MANUAL
Cross out
Default
setting
used
0
1
2
3
4
5
6
0
7
8
1-3
9
10
11
12
0
1
2
11
3
4-5
4
5
6
7
8
9
10
11
11
6-7
12
13
14
15
0
0
1
0
0
1
Radio channel control configuration
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as ped command.
Input configured as Timer command.
Input configured as Timer pedestrian command.
Input configured as phot (photocell) safety.
Input configured as phot op safety (photocell active during opening only).
Input configured as phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as safety Bar Op, safety edge with inversion active only while opening, if while closing
the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
Output configured as monostable Radio Channel.
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light.
Output configured as Alarm.
Output configured as Flashing light.
Output configured as Latch.
Output configured as Magnetic lock.
Output configured as Maintenance.
Output configured as Flashing Light and Maintenance.
Output configured as Traffic Light control with TLB board.
Not used
Output configured as gate Status
Output configured as Bistable Radio Channel
Output configured as timed Radio Channel
pre-flashing switched off.
Red lights flash, for 3 seconds, at start of operation.
Red lights off when gate closed.
Red lights on when gate closed.
Optional extras