Aprimatic RAIDER Instrucciones Para La Instalación página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7.2
RESET
If you want to return all the programmed parameters to their default settings, you should RESET as follows:
Switch OFF the power supply.
Press and hold down the BLUE button (scroll) and at the same time switch the power supply back ON
S will fl ash on the display
(exit) and the BLUE button (scroll) together for a few seconds (the self-teach function is described in par. 6.3).
7.3
FUNCTIONING LOGIC
AUTOMATIC LOGIC (default logic) (0)
Starting with the gate closed, the complete operating
cycle is as follows:
START pulse.
Wing 1 starts to open.
After 3 seconds, wing 2 starts to open.
When both wings are opened as far as the mechanical
stop, the gate will stay open for the programmed pause
period.
Wing 2 will then start to close.
After the programmed delay period, wing 1 will also
close.
During the operating cycle the system can manage the
following signals:
STOP pulse and START pulse.
Photocell for closing safety.
Opening safety device (photocell, safety edge ...).
Detection of any obstacle on the opening and closing
strokes.
Operation of the automation functions in response to these
signals depends on the functioning logic selected. The next
section describes the other functioning logic types.
The system functions with automatic logic of the default settings.
For instructions on changing the logic type, see par. 7.1.
The warning light signals the following gate functions
during the operating cycle: gate closed
or opening
on with steady light; gate closing
with fl ashing light.
4 STEP LOGIC (1)
Starting with the gate closed, the complete operating
cycle is the same as that for the automatic logic. If the
START pulse is not given within 3 seconds of the opening
pause, the gate will close automatically. If the START
pulse is given within the 3 seconds of pause time, the
gate will stay open and you will have to give another START pulse to close it.
SUPER AUTOMATIC LOGIC (2)
Starting with the gate closed, the complete operating cycle is the same as that for the automatic logic. The
START pulse given in any of the movement stages will reverse the direction of movement of the gate, making
the closure possible with the command.
SEMIAUTOMATIC LOGIC WITH STOP (3)
Starting with the gate closed, the complete operating cycle is the same as that for the automatic logic. Different
signal responses are possible.
STEP-BY-STEP LOGIC (4)
Starting with the gate closed, the complete operating cycle is as follows:
START pulse
wing 1 starts to open
far as the mechanical stop the gate stays open.
The START pulse must be given to close the gate
elapsed wing 1 closes too.
repeat the self-teach procedure as follows:
off; gate open
on
after 3 seconds wing 2 starts to open
press and hold down the YELLOW button
Automatic logic:
1
gate closed
2
gate open
1
wing 2 starts to close
- 33 -
Advanced programming
START pulse
2
3
gate opening
pause time
4
gate closing
1
2
when both wings are open as
after the set delay period has
the letter
Fig.26

Publicidad

Tabla de contenido
loading

Tabla de contenido