6.2A REMOTE COMMAND RECOGNITION WITH THREE-CHANNEL PL-ECO CONNECTION RECEIVER
Storing the fi rst remote command to memory
When the power supply is connected, the LED radio (Fig. 22)
fl ashes for 5 seconds (10 times) and then switches off.
Push all fi rst remote command buttons together
LED will light up (steady red) for 30 seconds. The learning
function is activated.
During these 30 seconds, push one of the remote command
buttons.
The LED will light up and the remote command
is stored to memory.
Store further remote commands to memory
Once the fi rst command has been learned, other commands
can be programmed:
Push all the remote command buttons already programmed
together.
The LED will light up (steady red) for 30 seconds
(the learning function is activated).
Push all the new remote command buttons.
turn off and the steady light will switch on again.
Push one of the remote command buttons.
complete.
If you do not store anything to memory, the LED will fl ash
after 30 seconds and the learning is fi nished.
Once all the remote commands have been programmed in,
the self-teach procedure can start.
Once the storage is complete, button 1 can be used for
the START command and button 2 for the PEDESTRIAN
START command (Fig.23).
6.2B RECOGNITION OF THE REMOTE COMMANDS WITH A MEMORY SYSTEM RECEIVER (SINGLE RECEIVER)
CAUTION The PL-ECO receiver must be removed from its place before you can use the Memory System receiver
(SINGLE receiver). Next, insert the UNICO receiver into the CN1 connector (Fig.21).
Perform the remote command teach procedure following the instructions supplied with the UNICO receiver.
6.3
SELF-TEACH CYCLE SYSTEM START-UP
When all the connections have been completed you must run the self-teach procedure in order to put the system
into service. If you do not complete the self-teach procedure, the automation will not work.
The gate must be CLOSED and STOPPED before you start the self-teach procedure; you can close the gate using
the DEAD MAN function as described in par. 6.
Proceed as follows to start the self-teach procedure:
Push the YELLOW (exit) and BLUE (scroll) buttons down
together for a few seconds, until the display confi rms that
the procedure has started by fl ashing 3 bars in a column.
The cycle starts; it consists of 5 stages:
full opening of wing 1 (or single wing);
full opening of wing 2 (if it is a double winged gate);
pause time;
full closing of wing 2 (if it is a double winged gate);
full closing of wing 1 (or single wing);
As the cycle is progressing, all external signals are
ignored, apart from the photocell during closing. If a
photocell command is received during this stage, the self-
teach procedure will be interrupted and will have to be
repeated.
At the end of the procedure the gate is closed and stopped and the display switches off.
Next, open or close the gate using the key button or remote command (if already stored to memory) to check that it
works properly. After the self-teach procedure, the system will function automatically following the default settings (see
par. 7.3).
Start up of the system and description of its functions
Fig.22
and the
Fig.23
The LED will
Storage is
1
Fig.24
- 31 -
Shield
antenna connector
radio LED
DO NOT MOVE!
2
1
3
AUTOAPPRESELF-TEACH
3 s"
Yellow
Blue
radio
RESET
CN2
2
4

Publicidad

Tabla de contenido
loading

Tabla de contenido