Electrical installation
6.1
SYSTEM ELECTRICAL CONNECTIONS
Make all the connections as indicated in the controller layout diagram (Fig.21). Connect the cables/wires to
their corresponding inputs.
WARNING! DO NOT use intercom cables.
IMPORTANT: Only connect up the 230 V AC network power supply when you have fi nished making all the other connections
and checks.
MOTORS - Two 24 V DC motors. Use two conductor cables with a section of at least 1.5 mm
POWER SUPPLY - 230 V AC MONOPHASE 50/60 HZ. According to current regulation you must use three conductor
cables with a section of 1.5 mm
rating of at least 10 A. The switch should have an omnipolar contact separation with a distance of at least 3 mm.
LED FLASHING LIGHT - 24V Connection by cable to two conductor cables of with section of 1 mm
IMPORTANT! DO NOT use other kinds of fl ashing lights to avoid damaging the system functions.
Fig.21
J4
F1
M5
L
N
PH
N
TRANSFORMER
J3 power supply terminal with inputs for 2 motors
J4 230 V AC connection connector
M5 230 V AC phase-earth-neutral connection
FS1 20 V AC connection
BATT 24 V DC battery connection
CN1 3-pin Aprimatic connector for accessory connection (UNICO
receiver, GSM UNICALL receiver, access control decoder, etc.).
CN2 10-pin connector for PL-ECO receiver
F1 fuse for primary transformer protection
F2 fuse for external accessory protection (24 V DC)
F3 fuse for electronic circuit protection
DISPLAY (7 segments and 1 point) for displaying
parameters and their values
2
(min.) for the power supply line. Upstream, fi t a overload or differential switch with a
CONTROLLER LAYOUT DIAGRAM
F2
F3
FS1
BATT
-
+
24 V AC
BATT
LEGEND
M1 = motor 1 st wing or single wing opening
M2 = motor 2 nd wing opening
= NO type contact
= NC type contact
CAUTION! The NC contacts must be jumpered to the earthing (terminal 9 or 11) when not
used. If they are not, the automation CANNOT OPERATE!
NOTA: the terminal 6 (NO) may become NC depending on the H parameter setting (par.7.1).
DL1
J3
M1 M2 M3 M4
1
2
M1
M2
MOTOR
MOTOR
1
2
12 Vac 15 W max.
S1 RED button = confi rm
S2 YELLOW button = exit
S3 BLUE button = scroll down available values
DL1 LED power supply signal
J1 card connection terminal (12 poles):
1-2 Electric lock - 12 V AC output with maximum connectable
load of 15W controlling the electric lock for approx. 1.5 seconds
in the opening stage.
3-4 LED fl ashing light at 24V DC.
5-4 Warning light - 24 V output max. load 3W for gate warning light.
6-9 Opening safety (NC) or Pedestrian start (NO).
7 24 V for ACCESSORIES.
8-9 Photocell input (NC).
10-9 Stop (NC) wing stopping command.
12-11 Start (NO) wing opening and/or closing command.
- 30 -