Amann Girrbach ceramill motion 2 Manual Del Usuario página 69

Ocultar thumbs Ver también para ceramill motion 2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

▷ Check if the door gasket is clean and free of
swarf/chips.
▷ Check if the C/L drain pipe is free of obstruc-
tions and if the piping on the outside is securely
connected.
6.1.2
Switching from Wet to Dry Processing
4
Fig. 19
1 Extraction hood
2 Lever of the extraction hood
3 Swarf sieve
4 Splash guard
5 Lever of the splash guard
B Service button
▷ Disengage lever [5] and pull off the transparent
splash guard [4] toward the front.
▷ Remove the swarf sieve [3].
▷ Clean and dry the milling chamber and the swarf
sieve (please refer to page 81).
A P P L I C A T I O N A N D O P E R A T I O N
▷ Mount the transparent splash guard [4] to the
extraction opening and lock it in place with lever
[5].
▷ Transfer the milling file for wet processing.
1
5
3
The swarf sieve [3] is not required for dry
processing.
▷ Insert the blank and insert or change the tool-
ing, as required.
▷ Mount the white extraction hood [1] to the
extraction opening and lock it in place with lever
[2].
▷ Check the air extraction.
▷ Transfer the milling file for dry processing.
2
B
E N
69

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ceramill coolstream

Tabla de contenido