Room Ventilation; Electrical Connections; Gas Connection; Water Connection - Riello MINI 11 Manual De Instalación

Ocultar thumbs Ver también para MINI 11:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
RIELLO MINI
RIELLO MINI 11 - 13
RIELLO MINI 17

3.5 Room ventilation

The appliance must be installed according to all the requirements in force
and subsequent updates. Being a type C sealed appliance, it is exempt
from the majority of the limitations deriving from room ventilation and can
also be installed in narrow rooms with no space volume restrictions.
3.6 Electrical wiring
Connect the cable supplied to the line, respecting the phase, neutral and
earth wiring. Should the power cable need to be replaced, this must be
carried out by a quali ed technician. Connect the device to a H03V2 V2-F
(3 x 0.75 mm
) max 7 mm Ø cable such as the one supplied; the earth wire
2
must also be 30 mm longer that the power cables. Power to the appliance
via an omnipolar switch with a gap of at least 3 mm between contacts.
For maintenance operations, disconnect the power supply by means of the
omnipolar switch.
We decline all responsibility for damage to persons, animals or ob-
jects deriving from the failure to earth the appliance or wire an elec-
trical system that complies with the standards in force.
A quali ed professional should check that the electrical system is suita-
ble for the appliance’s maximum absorbed power, as shown on the plate,
ensuring particularly that the section of the system cables is suited to the
appliance’s absorbed power.
Adapters, multiple sockets or extension cables should not be used to con-
nect the appliance to the mains.
Some basic rules apply to the use of any electrically powered component,
such as:
- do not touch the appliance with wet or damp body parts and/or with bare feet;
- do not pull the electrical cables;
- do not leave the appliance exposed to weathering (rain, sun, etc.);
- do not allow children or inexperienced individuals to use the appliance;
- the appliance’s power cable must not be replaced by the user.
Should the cable be damaged, turn off the device and seek assistance from
a quali ed technician to replace it.
Should it be decided not to use the appliance for a certain period of time, it
is recommended that you switch off the power supply to all system compo-
nents that require electricity.
Should you need to replace the power cable, use the cable supplied by the
manufacturer or the technical support service.

3.7 Gas connection

Establish the pipe diameter according to the standards in force.
Before installing the appliance, it is recommended that you blow the gas
piping so as to remove any processing waste. Connect the appliance to the
internal system gas pipe and insert a valve upstream of the appliance to
isolate and turn on the gas.
24
Appliances operating with LPG and powered by gas cylinders with isolation
and control devices should be connected in such a way as to guarantee the
safety of people and the surrounding environment.
You should ensure compliance with the current standards.
When starting up the appliance for the  rst time, have the following checks
carried out by a quali ed professional:
- a check on the internal and external gas delivery system seal;
- a check on the gas  ow rate according to the power required of the ap-
pliance;
- that the appliance is powered by the type of gas for which it has been
set up;
- that the gas power supply pressure is within the values shown on the
technical data plate;
 g. 4
- that the gas power supply system has been sized for the input necessary
for the appliance and that it is  tted with all of the safety and control de-
vices provided for by the standards in force.
In case of prolonged user absence from the appliance, shut off the
main appliance gas supply valve.
Do not use the gas tubes as an earthing system for electrical appli-
ances.

3.8 Water connection

Connect the appliance to the water mains and insert a water isolation valve
upstream of the appliance (available on request).
Looking at the appliance head on, the cold water inlet is to the right and the
hot water outlet to the left.
Ensure that the water system pipes are not used as earthing for your
electrical or telephone system. They are in no way designed for this
purpose. Using them in this way may cause serious damage to the
 g. 4a
pipes and the appliance itself in a short space of time.

3.9 Gas conversion

Converting gas from one form to another can be done easily, even with the
appliance already installed.
Conversion must be carried out by trained and quali ed person-
nel according to the regulations in force.
The boiler is supplied to operate with methane gas (G20) or with LPG (G30/
G31), according to the indications on the product data plate.
The appliance can be converted from one type of gas to another using one
of the speci c kits provided on request:
- Methane conversion kit
- LPG conversion kit.
RIELLO MINI 11-13
RIELLO MINI 17
( g. 5-5a)
 g. 5
 g. 5a

Publicidad

Tabla de contenido
loading