4
Install the conduit connectors and conduit to the external
blower housing and range hood electrical terminal boxes.
NOTE: If removed, install the range hood transition.
5
Connect the vent system to the range hood and external
blower system. Seal all joints with clamps.
6
Once the electrical connection is made, place the kit
front cover with the neoprene washers and the
blower mointing screws.
IWARNING
For the correct use of your product, you must install the
neoprene washers to avoid the water entrance.
C
D
A. Blower mointing
screws
B. Neoprene washers

ELECTRICAL CONNECTION INSTRUCTIONS

Electrical Connection for External
Blower Motor System
I WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
I WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in
terminal box.
Failure to do so can result in death or electrical shock.
NOTE: The electrical diagram is attached at the end of the
document.
Electrical Connection Inside External Blower System
1
Disconnect power.
2
Connect the wires from the wiring conduit to the wires
from the motor electrical plug cable inside the external
blower housing terminal box.
3
Use UL listed wire connectors and connect the black wires
(C) together.
4
Use UL listed wire connectors and connect the white wires
(D) together.
5
Use UL listed wire connectors and connect the red wires
(E) together.
6
Use UL listed wire connectors and connect the blue wires
(F) together.
7
Use UL listed wire connectors and connect the gray wires
(G) together.
10
C. Front cover
D. External Blower
A
B
8
Connect the green (or green/yellow) ground wire from the
wiring conduit to the green (or yellow/green), ground wire
(H) in the terminal box using UL listed wire connectors.
A
A. Strain relief
B. UL listed wire
connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
B
C
D
E
F
G
H
I
G. Gray wires
H. Green (or yellow/
green) and green /
yellow wires
I. Motor electrical plug