6.8

System messages

The 4-digit system message is displayed as two groups of two digits appearing in succession.
System message
Functions that
are still available
Er11
Container cover raised
Er22
Water temperature > 12 °C
AND the last automatic
cleaning process was carried
out more than 24 hours ago.
Er33
20 cleaning cycles in
succession
56
Possible cause
Manual cleaning
Container cover raised
(only nozzles,
Container cover incorrectly fitted
filter drum not
rotating)
Signal box not connected
Manual cleaning
Screen elements leaking
Automatic mode
Drum seal leaking
Time-dependent
cleaning
Level detection device stuck or defective
Level detection device set incorrectly
Manual cleaning
24 hour check mode is active and time-dependent cleaning
Automatic mode
is deactivated.
Manual cleaning
Level detection device stuck or defective
Time-dependent
cleaning
Screen elements heavily soiled
Rinsing pump not operating
Rinsing nozzle clogged
Filter drum not rotating
Level detection device set too low
Water level in the system too high:
Outlet pipes soiled
Outlet opening too small
Excessive flow quantity (pump capacity too high)
The pond water is very dirty and the filter pump is
conveying an excessive amount of dirt.
A large amount of dirt has entered the filter system, water
is flowing over (instead of through) the foam filters.
Remedy
Refit the container cover
Turn the container cover around so that the magnets in
the container cover are located over the signal box
Connect the signal box to the control system
Check screen elements, replace if necessary
Check the drum seal
Clean the level detection device to ensure that the
mechanics operate freely, replace if necessary
Adjust the level detection device (→ Adjusting the level
detection device)
Time-dependent cleaning is automatically activated by
floats after check mode.
Clean the level detection device to ensure that the
mechanics operate freely, replace if necessary
Clean/descale the screen elements (→ Removing/fitting a
screen element)
Clean the bottom of the container, clean the rinsing
pump (→ Cleaning the rinsing pump)
Check the pump connection
Clean the rinsing nozzle
Check the motor connection
Check the rotating movement of the filter drum.
Tip: Mark the filter drum and check on the basis of the
markings if the drum rotates.
Adjust the level detection device (→ Adjusting the level
detection device)
Clean outlet pipes
Enlarge outlet opening
Reduce flow quantity (adjust pump capacity)
Thoroughly clean the pond.
Install the pump in an elevated position.
Clean foam filters
Resetting the system
message
Automatic when the
container cover is
replaced
On|Off
Press
key for
5 s
Automatic as soon as
the level detection
device is triggered
On|Off
Press
key for 5 s