Beretta 30 B.S.I. Manual De Instalacion Y Uso página 13

Ocultar thumbs Ver también para 30 B.S.I.:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
Information
Press , the display turns off and just the word InFO appears (fig.
32). Press the button
to view operating information. Press the
button again to move on to the next piece of information. If the
button is not pressed, the system automatically exits the function.
Info list:
Info 0
shows the word InFO (fig. 32)
32
Info 1
only with the external probe connected, displays external
temperature (e.g. 12 °C) (fig. 33).
The values shown on the display range between - 30 °C
and 35 °C.
Beyond these values the display shows "- -"
33
Info 2
shows circuit pressure (fig. 34)
34
INF2
It is possible to display information, which may be useful for the
Technical Assistance Centre, by pressing the button
seconds: the code "INF2" appears on the display.
INF2 list
Step
Description
1
Input probe temperature
2
Return probe temperature
3
First water tank probe temperature (*)
4
Not used in this model
5
Fumes probe temperature
6
Second heating system probe temperature
7
Not used in this model
8
Ventilator speed /100
9
Not used in this model
10
Not used in this model
11
Exchanger cleaning counter status
12-19 Historic alarm codes
Note (*): if the water tank probe is faulty or disconnected, in the place of the value "- -" is displayed.
(**): if the display also shows the dot (.), the temperature of the fumes probe is 100+displayed value
Info 3
shows the set heating temperature (fig. 35)
35
Info 4
shows the set domestic hot water temperature (fig. 36)
36
Info 5
displays the set heating temperature, in reference to the
second circuit, only if it is connected.
S.A.R.A. function
If the "winter" mode is selected, the S.A.R.A. (Automatic Ambient
Adjustment System) function can be activated.
Turning the heating water temperature selector to a temperature
ranging between 55 and 65 °C the S.A.R.A. self-adjustment system
activates: depending on the temperature set on the ambient thermostat
and the time taken to reach it, the boiler automatically adjusts the
heating water temperature to reduce operating times, thereby
increasing operating comfort and energy saving.
37
for 10
Display
Display
2 digits
4 digits
xx
01
xx
02
xx
03
xx
Cond
xx (**)
05
xx
06
xx
07
xx
FAN
xx
09
xx
10
bH
xxxx
xx
HIS0-HIS7
ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
° C
° C
° C
° C
° C
1 3
1 3
1 3
1 3
1 3