Charcoal Filter - Viking RDMOR206 Manual De Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

cHarcoal filtEr

Charcoal Filter is used for Non-vented, recirculated installation. The filter should
be changed every 6 to 12 months depending on use.
1. Disconnect power to the oven at the circuit breaker panel or by unplugging.
2. Remove 2 screws that secure louver.
3. Remove louver by gently moving louver and pull away from unit.
4. Remove 2 screws that secure the sensor duct cover.
5. Remove the sensor duct cover.
6. Remove old charcoal filter (if one is installed).
7. Slide new charcoal filter into position on the support tabs.
8. Reattach sensor duct cover and secure with 2 screws.
9. Push louver back into place and replace the 2 screws to secure louver.
Sensor duct cover
Charcoal filter
E41

Publicidad

Tabla de contenido
loading

Tabla de contenido