Mediclinics M14A-UL Manual De Instalación Y Utilizacion página 14

Secadora de manos
Ocultar thumbs Ver también para M14A-UL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance.
ONLY A QUALIFIED TECHNICIAN CAN INSTALL, ADJUST AND MAINTAIN THIS HAND
Adjust the speed of the motor.
To adjust the speed of the motor turn the sensor potentiometer wheel as the picture 4 shows.
Disconnecting the heating element.
The heating element may be disconnected by switching the switch to (OFF) as shown in Fig. 4
Information relative to the pilot lights.
Light leds on the top of the hand dryer (see figure 5) give advice about:
1: The unit in standby (green colour) or operating (orange colour).
2: Red colour led brigths when motor has a problem of consumption (due to brushes
which may be wearing out or due to a blocked or locked sate of motor).
3.- The blue led illuminates when the water tank is full, indicating that the tank must be
emptied.
DRYER.
Figure 4
Figure 5