Control Panel; Food Preparation Instructions; Minimum Filling - all-clad PC8-PRECISION Guía Del Usuario Y Información De Garantía

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Control panel

• The removeable control panel is designed to make it
easier to clean your PC8-PRECISION.
• The pot and lid are dishwasher safe once you remove
the Smart Timer
• The control panel comprises all of the components
needed for your PC8-PRECISION to operate.
Once mounted on the lid, your PC8-PRECISION
can be used normally.
To remove the control panel from the lid:
• Turn the lid over.
• Unscrew the module retaining nut using a coin,
while holding the module in the other hand.
• Turn the lid over and remove the control panel.
To fit the control panel on the lid:
• Position the crown on the lid, with the vent for the
automatic air ventilation system (B) aligned over the
grey valve.
• Position the module, with the handle down, on the lid.
• Turn the complete assembly over while holding the
module against the lid and tighten down the
retaining nut using a coin.
The crown and control panel will only fit one way.

Food Preparation Instructions

Never use PC8-PRECISION without the crown.
Do not fill the unit over ⅔ full. When cooking foods that expand during cooking
such as rice or dried vegetables, do not fill the unit over ½ full. Over filling may
cause a risk of clogging the vent pipe and developing excess pressure.
Food placed in
the steaming
basket must not
touch the
PC8-PRECISION
lid.
4
®
, the control panel and the gasket.
When cooking directly in the cooker:
• Always pour a minimum amount of liquid of at least 1 cup
into the PC8-PRECISION.
For steaming:
• At least 3 cups of water must be poured in.
• Place your steaming basket filled with food into the
bottom of the pot.
If your PC8-PRECISION was heated without any liquid
inside:
• Have your PC8-PRECISION inspected by a All-Clad
approved service center.

Minimum filling

Fig. 3
Fig. 5

Publicidad

Tabla de contenido
loading

Tabla de contenido