correct way of disposing by checking with local codes.
Also, observe the relevant environmental protection
regulations when disposing of oil, fuel, coolant,
brake fluid, filters and batteries.
RADIATOR HO E & CLAMP
Check to see that radiator hoses are secure and clamps are
tight every 200 hours and replace if hoses are swollen or
cracked. If clamps are loose, apply oil to the threads and
retighten securely. Replace hoses and clamps every two years.
ENGINE FAN BELT
Check belt tension at the first 50 hours and then
every 100 hours. Apply moderate thumb
pressure 22lbs (98N) at the center of the longest
free length (A). The correct deflection is .28 to
.35 in. (7-9mm). Replace if worn.
Adjusting Engine Fan Belt
1. Loosen the pivot fasteners of the
alternator and the adjustment link
fasteners.
2.
Change the position of the alternator
to give the correct tension. Tighten the
and the adjustment link fasteners.
3. Check the belt tension again to ensure that it is still correct. If a new belt is fitted,
the belt tension must be checked again after the first 50 hours of operation.
VALVE CLEARANCE
adiator hoses
Fan belt adjustment
pivot fasteners of the alternator
Maintenance
WolfPac
6100
TM
49