Thank you for choosing our product. FAAC is sure that it will give you
all the performances you are looking for. All our products are the
result of a long experience in the field of the automated systems.
In the middle of the handbook you will find a detachable
brochure with the images for the installation.
The 413 automated system for swing gates is an electro-mecha-
nical non-reversing operator that transmits motion to the leaf via
a worm screw system.
The operator is available in several versions. The "LS" versions are
equipped with opening and closing limit switches. Every version is
supplied with opening and closing mechanical travel stops.
The non-reversing system ensures the leaf is mechanically locked
when the motor is not operating. A convenient and safe release
system with customised key makes it possible to manually move the
leaf in the event of a malfunction or of a power failure.
IMPORTANT NOTES FOR INSTALLER
•
Before starting the installation of the operator read this manual
completely.
•
Keep this manual for future reference.
•
Smooth operation and specifications are obtained only declared
following the directions given in this handbook and with acces-
sories and safety devices FAAC.
•
The lack of a mechanical clutch device requires to ensure an
adequate level of security automation, the use of a central control
device with an electronically controlled clutch.
•
The automation was designed and built to control vehicular
access. Avoid any other use.
•
The operator can not be used to handle emergency exit routes
or gates installed on emergency (escape routes).
•
If there is built-in anti motorize from a door to the walkway is requi-
red to add a safety switch on the door, connected on the entry
of STOP , to inhibit the operation of automation with door open.
•
Everything that is not expressly stated in this manual is not al-
lowed.
1. DESCRIPTION (Fig. 1)
Pos.
Operator
a
Release device
b
Limit switch cover
c
Closing limit switch
d
a
Opening limit switch
e
a
Front bracket
f
Rear fitting
g
Rear fitting pin
h
Rear bracket
i
Terminal board cover
j
Only where "LS"
a
2. TECHNICAL SPECIFICATIONS
Technical specifica-
tions
Power supply
230 V~
Power (W)
250
Current (A)
1.1
Thermal protection
140
(°C)
Capacitor (µF)
6.3
Thrust (daN)
200
Rated thrust (daN)
140
Travel (mm)
Speed (cm/sec)
Noisiness (dBA)
Leaf max. (m)
Type and use fre-
S3
quency at 20° C
30%
Description
Model
24 V
115 V~
70
260
3
2.2
/
140
/
20
250
200
170
140
300
a
1.6
1.85
<70
2.5
b
S3
S3
100%
35%
30%
Technical specifica-
tions
Approximate min.
cycle/hour at 20° C
Operating ambient
temperature (°C)
Operator weight (Kg)
Operator dimensions
(mm)
Protection class
If no closing and opening mechanical travel stops are used, the
a
operator travel is 350 mm.
With leaves exceeding 1.8 m the fitting of an electric lock is
b
required to ensure the leaf locking.
2.1. Versions
Model
230V~ operator with opening/closing mechanical
413
travel stops
230V~ operator with opening/closing mechanical tra-
413 LS
vel stops and opening/closing limit switches
24V operator with opening/closing mechanical travel
413 24V
stops
24V operator with opening/closing mechanical travel
413 LS 24V
stops and opening/closing limit switches
115V~ operator with opening/closing mechanical
413 115V
travel stops
115V~ operator with opening/closing mechanical tra-
413 LS 115V
vel stops and opening/closing limit switches
For CSA-UL approved operators, control unit 455 MPS UL 115
must be used in order to maintain the approval.
3.1. Electrical set-up (standard system Fig. 3)
Pos.
Description
Operators
a
a
Control unit
b
TX photocells
c
RX photocells
d
Key-operated selector switch
e
Flashing lamp
f
Receiver
g
Mechanical stops on the ground
h
The value in parentheses refers to the motors at 24 V
a
The value in parentheses refers to the switch with two contacts
b
Use suitable tubes and/or hoses to lay electric cables
To avoid any kind of interference always separate low-vol-
tage accessories and control cables from 230/115 V~ power
supply cables using separate sheaths.
3.2. Preliminary checks
To ensure a correct operation of the automated system, make sure
the following requirements are observed as for the gate structure
(existing or to be realised):
•
the mechanical parts must conform to the provisions of Standards
EN 12604 and EN 12605.
•
leaf length in compliance with the operator specifications.
•
sturdy and stiff structure of the leaves, suitable for automation
•
regular and uniform movement of the leaves, without any friction
and dragging during their entire opening.
•
stiff hinges in good conditions.
•
presence of both opening and closing mechanical limit stops
(they are not necessary if opening and closing mechanical travel
S3
stops are used).
35%
•
presence of an efficient earthing for electrical connection of
413
Guide for the installer
Model
~ 30
~ 100
-20 +55
6.5
See Fig. 2
IP54
Version
3. INSTALLATION
Cables section
4x1.5mm
3x1.5mm
(power supply)
2x0.5mm
4x0.5mm
2x0.5mm
b
2x1.5mm
3x0.5mm
Page
~ 30
(2x1.5mm
)
2
2
2
2
2
(3x0.5mm
)
2
2
2
2