TABLE "B" - LOGIC MENU - (logic)
Logic
Definition
Motor type
(Set the type of motor
OTOR TYPE
connected to the
board).
Automatic Closing
TCA
Time
Fast closing
FAST CLS.
STEP-BY-STEP
Step-by-step
movement
OVE NT
Pre-alarm
PRE-ALAR
Deadman
HOLD-TO-RUN
Block pulses during
IBL OPEN
opening
Block pulses during
iBL TCA
TCA
Block pulses during
IBL CLOSE
closing
Hammer during
RA
BLOW C. O P
opening
Hammer during
RA
BLOW C. C L
closing
Stop maintenance
BLOC PERSIST
Closing limit switch
PRESS SWC
pressure
Ice feature
ICE
1 motor active
1
OT. O N
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Motors not active
1
ELI 250 BT
2
PHOBOS N BT
3
IGEA BT
4
NOT MANAGED
5
NOT MANAGED
6
SUB BT
7
KUSTOS BT A - PHOBOS BT A
0
8
GIUNO ULTRA BT A 20 - GIUNO ULTRA BT A50
9
VIRGO SMART BT A - 5 wires
10
VIRGO SMART BT A - 3 wires
11
E5 BT A18
12
E5 BT A12
13
ELI BT A40 LS
14
ELI BT A35 LS
15
ELI BT A35
16
ELI BT A40
0
Logic not enabled
0
1
Switches automatic closing on
0
Logic not enabled
0
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
0
Inputs configured as Start E, Start I, Ped operate with 4-step logic.
0
1
Inputs configured as Start E, Start I, Ped operate with 3-step logic. Pulse during closing reverses movement.
2
Inputs configured as Start E, Start I, Ped operate with 2-step logic. Movement reverses with each pulse.
0
The flashing light comes on at the same time as the motor(s) start.
0
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
0
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
2
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
Logic not enabled
Before opening completely, the gate pushes for approx. 2 seconds as it closes. This allows the solenoid
0
1
lock to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
0
Logic not enabled
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows the solenoid lock
0
1
to be released more easily.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
0
Logic not enabled
If motors stay idle in fully open or fully closed position for more than one hour, they are switched on in
the direction of the stop for approx. 3 seconds. This operation is performed every hour.
0
1
NB: In hydraulic motors, this function serves to compensate a possible reduction in the volume of oil due
to a drop in temperature during extended pauses, such as during the night, or due to internal leakage.
IMPORTANT - Do not use this function if suitable mechanical stops are not in place.
Movement is stopped only when the closing limit switch trips: in this case, the tripping of the closing
0
limit switch must be adjusted accurately (Fig.G Ref.B).
Use when there is a mechanical stop in closed position.
This function allows leaves to press against the mechanical stop without the Amperostop sensor inter-
0
preting this as an obstacle.
1
Thus the rod continues its stroke for a few seconds after meeting the closing limit switch or as far as the
mechanical stop. In this way, the leaves come to rest perfectly against the stop by allowing the closing
limit switches to trip slightly earlier (Fig.G Ref.A).
0
The Amperostop safety trip threshold stays at the same set value.
The controller automatically adjusts the obstacle alarm trip threshold at each start up.
Check that the force of impact measured at the points provided for by standard EN 12445 is lower than
0
the value laid down by standard EN 12453. If in doubt, use auxiliary safety devices.
1
This feature is useful when dealing with installations running at low temperatures.
WARNING: once this feature has been activated, you will need to perform an autoset opening and closing
cycle.
0
Both motors active (2 leaves).
0
1
Only motor 1 active (1 leaf ).
Optional extras
35
THALIA -