4.3
Compressed air connection
1. Connect the FALCO EVO 622/622 IT to the com-
pressed air supply.
i
With a bayonet catch it is sufficient to move the com-
pressed air hose to the connection of the filter unit
and fasten the bayonet catch.
Fig. 15:
Compressed air connection
2. Set a pressure of 8 – 10 bar.
First pull the pressure reducer (red knurled
screw) upwards, then turn to set a pressure of
8 – 10 bar .
Check the pressure on the pressure gage.
!
The scope of delivery also includes a quick-release
coupling with 1/4" thread to enable a compressed
air connection to be made even if no bayonet catch
is available.
3. Use a 14 mm wrench to remove the swivel connec-
tion at the filter unit.
Fig. 16:
Removing swivel connection
4. Pull out the swivel connection and attach the quick-
release connection. Then tighten with a 14 mm
wrench.
Sicam srl società unipersonale
Commissioning | FALCO EVO 622/622 IT | 41
!
Fit the original seal back in position.
Fig. 17:
Fitting quick-release connection
!
For setting the lubricating oil flow, see Sec. 6.2.6.
en
|
1 695 101 508