Dovre VINTAGE 35GA Instrucciones De Instalacion Y Uso página 91

Ocultar thumbs Ver también para VINTAGE 35GA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 196
Subject to change because of technical improvements
Problem
Thermocouple
Replace the thermocouple (*).
faulty
No spark
Spark but no ignition
When ignition button is released, pilot goes out
Main burner does not ignite
Whistling between high and low setting
Disrupted flame effect
Gas smell
Smell of combustion gases in room
Appliance goes out
Remote control does not work
possible
possible solution
cause
(*) = have installer carry out this action
Electromagnetic
Replace the control block (*).
valve faulty
Blocked pipes or
Blow through the parts and clean them (*).
nozzles
Burr on nozzle
Remove the burr (*).
Clean the burner, check the placement of the logs, remove any
Dirty burner
coal from the burner openings (*).
Gas leak
Close the main valve, find the gas leak and repair the leak (*).
Blocked smoke
exhaust pipe or air
Check the pipes and clean them (*).
intake pipes
Stove is leaking air
Check the door seals and appliance joints (*).
Dust on combustion
Clean the combustion chamber.
chamber
Empty batteries
Replace the batteries.
Wiring to gas block
Trace any bad contact point and repair it.
Faulty transmitter or
Replace the remote control.
receiver
45

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vintage 50ga

Tabla de contenido