Floors And Walls; Product Description - Dovre VINTAGE 35GA Instrucciones De Instalacion Y Uso

Ocultar thumbs Ver también para VINTAGE 35GA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 196
be larger or smaller than the specified limits at any
place. The section may vary over the whole length
of the flue pipe on the condition that the transitions
in section occur gradually.
If this last condition cannot be satisfied, the pipe
may be lined with stainless steel flexible piping
with a diameter of 150 to 250 mm, which is heat-
resistant to 600°C before it can be converted into
an air intake pipe.
The flue pipe must be closed at the top and bottom
with the recommended flanges (mounting plates).
The bottom of the flue section must always be con-
nected to the appliance using a concentric duct sec-
tion and the prescribed roof outlet must always be
mounted on the outlet side.
The maximum allowable length, including the con-
nection section (resistance length), is 12 metres.
Every elbow of 90° corresponds to 1 metre of resis-
tance length and every elbow up to 45° cor-
responds to 0.5 metres of resistance length.

Floors and walls

The floor on which the appliance is placed must have
sufficient bearing capacity. For the weight of the appli-
ance, see the appendix "Technical data".
Keep sufficient distance between the appli-
ance and combustible materials such as
wooden walls and furniture.
Carpets and rugs must be at least 80 cm away
from the fire.
For further requirements in connection with fire
safety: see the appendix "Distance from com-
bustible material".
6

Product description

1
2
3
4
5
1. Mirror
2. Ceramic wood block set
3. Door
4. Leg
5. Glass pane
6. Burner
7. Gas connection
8. Top plate
9. Concentric connection collar top or rear
Stove features
The Vintage GA is a stand-alone closed gas stove.
A closed apparatus does not draw the combustion
air from the room in which the stove is placed but
uses outside air. The stove is connected to a com-
bined air intake/flue gas exhaust system. The
stove can be connected to a C11, C1 or C91-type
chimney system. The stove is fitted with a Muelink
& Grol connection collar for concentric ducts.
Thanks to this concept, the stove is suitable for the
use in crack-free and well-insulated homes.
Delivery of the stove includes a battery-operated
wireless remote control with thermostat.
The appliance comes with electronic ignition.
The stove is delivered with a ceramic true-to-life
wood block set and is equipped with a black mirror
at the rear and the sides for an even livelier flame
effect.
Subject to change because of technical improvements
9
8
7
6
09-20020-184

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vintage 50ga

Tabla de contenido