Menu index 3B2 Redox (ORP) FREQU OUT
3B2 FREQU OUT Redox
SET POINT:
TYPE DOSE:
PULSE:
Item
FWM Standard:
SetPoint:
Dose Type:
Pulses/minute:
Proportional Band:
The frequency output (Open collector circuit) can be used to control and guide the dosing of a remote
system in proportion to the Redox measurement.
Menu index 3B3 Redox OUT Current Output
3B3 mA OUT PH
RANGE:
START(4):
END
(20):
Item
Standard Out mA:
Range 0/4-20mA:
Start (4): 0 pH
End (20): 14 pH
Hold Function mA
Value: 0/4 or 20 mA
Note: The value set under the HOLD mA item is automatically generated by the instrument when a functional Hold
is present, for example due to a lack of water Flow Alarm or an enabled Voltage Input.
Menu index 3B4 Redox ALARMS (level probe alarm only available on pH and Redox systems)
3B4 CHLORINE ALARMS
MIN VAL.:
MAX VAL.:
HOLD ALARM:
Item
pH Alarms List
Alarm minimum:
Alarm Maximum:
OFA (Maximum dose timer):
Holding range:
Holding time:
Level Alarm: System stop or
alarm display
Note: The Holding Range and Holding Time items must be used together.
The indicated function controls the chemical measurement at a constant value for long periods of time.
This alarm can help to prevent incorrect dosing as a result of damaged probes.
0000137242
"This menu is available on the pH–Redox System version"
700 mV
LOW
20/min
700 mV
Low
20 pulses/minute
200 mV
"This menu is available on the pH–Redox System version"
4-20 mA
000 mV
999 mV
4-20 mA
0 mV
999 mV
0 mA
100 mV
800 mV
↓ ↓ ↓ ↓
OFF
100 mV
800 mV
Off
Off
Off
Disabled
3B2 FREQU OUT CHLORINE
TYPE DOSE:
PULSE:
↓ ↓ ↓ ↓
PROP BAND:
Default Value
3A3 mA OUT PH
START(4):
END
(20):
↓ ↓ ↓ ↓
HOLD mA:
Default Value
3B4 CHLORINE ALARMS
HOLDING RANGE:
HOLDING TIME:
LEV ALARM:
Default Value
Rev. 6.0
LOW
20/min
200 mV
Range
To be verified
High / Low
20-150 pulses/minute
To be verified
0.00ppm
900 mV
20.0 mA
Range
0-20 mA or 4-20 mA
Review
Review
0-20 mA
OFF
OFF
DISABLED
Range
Review
Review
10-3600 Seconds
0.2-3 ppm
10-3600 Seconds
Enabled/Disabled
(Available with the pH-Redox
System version)
↑ ↑ ↑ ↑
↑ ↑ ↑ ↑
↑ ↑ ↑ ↑