SPECIFICATIONS
Weight:
•
Power supply:
•
Consumption:
•
Fuse:
•
Protection level:
•
I
WARNING: BEFORE DOING ANY WORK ON THE PUMP, ALWAYS FIRST DISCONNECT THE
I
WE RECOMMEND INSTALLING THE PUMP IN A VERTICAL POSITION TO ENSURE PROPER
I
WARNING: PRODUCT INTENDED FOR PROFESSIONAL USE BY SKILLED PERSONNEL.
I
WARNING: MAINTENANCE WORK ON THE PUMP MUST BE CARRIED OUT BY AUTHORISED AND
H
SO
SULPHURIC ACID All the pumps are tested with water. Before dosing chemical products that may react
-
2
4
with water, dry all the internal parts of the plumbing thoroughly.
-
Install the pump in a zone where the environment temperature does not exceed 40ºC and the relative humidity is below
90%. The pump has an IP65 protection level. Avoid installing the pump directly exposed to sunlight.
-
Install the pump so that any inspection and maintenance operations are easy to carry out, then secure the pump firmly in
order to prevent excessive vibrations.
Check that the power supply available in the network is compatible with that indicated on the pump label.
-
WIRING
A
EM00136319
1.5 Kg
230 Vac (50 Hz)
12 W
2A 250V T 5x20
IP65
READ THE FOLLOWING WARNINGS BEFORE INSTALLING
OR PERFORMING MAINTENANCE ON THE PUMP.
POWER SUPPLY CABLE.
OPERATION.
TRAINED PERSONNEL ONLY.
Input A
Power supply 230Vac
(50 Hz)
The pump must be connected to a power supply that
complies with the information indicated on the label on
the side of the pump. Failure to respect these limits
may cause damage to the pump itself.
The pumps have been designed to absorb small over
voltages. Therefore, in order to prevent the pump from
being damaged, it is always preferable to ensure that
the pump does not have a power source shared with
electrical appliances that generate high voltages.
Connection with the three-phase 380V line should
only be made between phase and neutral.
Connections MUST NOT be made between phase
and ground.
rev.2.0
EN
2