2.9.2

Dry running

If run dry, mechanical seals and synthetic parts can be destroyed
within only a few seconds.
Do not allow the pump to run dry. This also applies to
checking the rotation direction.
Purge air from pump and suction line prior to start-up.
2.9.3

Overheating

The following factors can result in the pump overheating:
Motor overload switch set incorrectly.
Air vents blocked by leaves, branches, ...
Lack of insulation wall.
For pumps with a three-phase motor, install a built-in or
external overload switch and set it correctly.
Only operate the unit with the insulation wall (55) installed.
Do not exceed the permitted ambient temperature of 40 °C.
2.9.4

Blockages in the pump

Pieces of dirt in the suction line can clog and block the pump.
Remove foreign matter (branches, leaves, clothes, ...) from
the suction opening.
Check how easily the pump rotates before starting it up and
after longer idle or storage periods.
2.9.5

Drainage

An insufficient drain gap can damage the motor.
Do not block or seal the drain gap between the pump
housing and the motor.
2.9.6

Risk of frost

Drain the pump/unit and pipes at risk of freezing in plenty of
time.
Remove the pump/unit during periods of frost and store it in a
dry room.
2.9.7

Water temperature

The water temperature must not exceed 35 °C.