Faults
7.1.1

Check the pump after the overload switch has tripped

If the motor has been switched off by the built-in or external
overload switch, carry out the following steps:
1.
Disconnect the system from the power supply.
2.
Turn the motor shaft on the fan side using a screwdriver and
check whether it turns easily.
If the motor shaft is difficult to turn:
1.
Remove the screwdriver.
2.
Notify Customer Services or your swimming pool builder and
have the pump tested.
If the motor shaft is easy to turn:
1.
Remove the screwdriver.
2.
Reconnect to the power supply.
NOTICE
If the pump seizes and is repeatedly switched on, the motor can
be damaged.
Ensure that the pump/unit is only switched on once.
3.
Wait until the built-in overload switch automatically switches
the motor on after it has cooled down.
– or –
Reset the motor overload switch.
4.
Have an electrician test the power supply, fuses and power
consumption.
5.
If the built-in or external overload switch switches the motor
off again, notify Customer Services.
7.1.2

Spare parts lists

Spare parts lists for each pump can be found on the website
www.speck-pumps.com.