Adjust minimum diameter of the electrical pipes to
accommodate the motor output and pipe length.
If hazardous situations can occur, provide an emergency off
switch according to DIN EN 809. The builder/operator must
make a decision according to this standard.
5.3.1
Connection by customer
WARNING
Danger of electric shock!
The motor housing must be connected to the equipotential
bonding (ground strap). There is an appropriate clamp on the
motor housing.
•
ground fault circuit interrupter I
•
1-phase 230 V/3-phase 400 V 16 A time delay fuse or 16 A
circuit breaker
•
All-pole emergency switch off with 0 and 1 label
Further information is provided in the connection diagram. The
above-mentioned parts are not included in delivery and must be
provided on site for the installation of the unit.
Fig. 9
09|2018
≤ 30 mA
FN
Installation
EN 23