salmson ACSON VARIO Instalacion Y Puesta En Servicio página 31

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Display
ROTATION SENSE
0
Hz
MIN SPEED
30
HZ
DRY RUN PROT
NO
PRESSURE SETTING
2,0
BAR
START DELTA P
0,3
BAR
TIME BEFORE STOP
5
S
DISPLAY
STANDARD
RUNNING TIME
HOURS
26H
Installation and starting instructions Salmson ACSON VARIO
Menu level 1
Menu level 2
ROTATION
SENSE
MIN SPEED
DRY RUN PROT
PRESSURE
SETTING
Start delta P
TIME BEFORE
STOP
DISPLAY
HISTORIC
RUNNING TIME
Description
Setting of the rotation
sense. See the pump
identification plate.
Push on
to start
the pump (at 30hz)
and check the rotation
sense.
Define the minimum
motor rotation speed
If the installation is
provided with a level
switch (flow switch or
other ones) change NO
by YES.
Working pressure set-
ting in the installation
Define the starting
pressure as : starting
pressure = setpoint
pressure - start delta
P.
Time setting before
pump stop when there
is no flow.
Define the display
mode :
• STANDARD:network
pressure (bar) +
pressure setting
(bar)
• SERVICE : rotation
frequency (Hz) +
pressure setting
(bar) + networkpres-
sure (bar) + flow
switch detection (1
or 0)
Total pump running
hours (H).
English
25

Publicidad

Tabla de contenido
loading

Tabla de contenido