English
Display
PUMP CYCLES
30
POWER ON
30
MAX PRESSURE
0,0 BAR
ALARM COUNT
SHT CIRCUIT 15
ALARM COUNT
OV CURRENT 10
ALARM COUNT
OVER T
ALARM COUNT
DRY RUN
6.3.2 Manual mode
We can access to this mode via the push-button
This mode is fugitive and you shall keep pushing on the push-button
it working.The pump starts at maximum frequency. When releasing it the pump
slows down up to complete stop.
6.3.3 Automatic mode
This mode allows an automatic setting of the pressure whatever the flow is.
You can access to this mode by pushing on the push-button
on.
The working condition of this mode can be set in the SETTINGS menu.
7 Installation and electrical connection
DANGER! Risk of death!
An improper installation and electrical connections can result in a risk of fatal
injury.
• The installation and electrical connections should only be done by a qualified
electrician and in compliance with the regulations in force.
• Follow all accident prevention regulations!
• Before installation and electrical connection, switch off the product/station
shall (no voltage) and be sure it cannot be switched on again without any con-
trol!
• Disconnect the mains plug!
26
Menu level 1
5
6
Menu level 2
Description
PUMP CYCLES
Total number of pump
cycles, one cycle
includes one start and
onr stop.
POWER ON
Number of Acson Vario
switching on
MAX PRESSURE
Storage of the maxi-
mum pressure reached
in the installation (bar).
ALARM COUNT
Total number of short
SHT CIRCUIT
circuits
ALARM COUNT
Total number of over-
OV CURRENT
currents
ALARM COUNT
Total number of
OVER T
exceeding
temperatures
ALARM COUNT
Number of dry running
DRY RUN
. The led
is off.
to get
. The led
is
Pompes Salmson 08/2013