7.6 MAINTENANCE PROGRAMME

The following Maintenance Programme shows all the maintenance jobs
that need doing to keep the pump in optimum operating conditions.
Maintenance must be carried out by technicians and/or qualified
personnel, adequately trained and supplied with the necessary equipment.
ATTENTION: observe all the safety conditions when handling the
items.
ATTENTION: dispose of oil and any waste material in
accordance with current laws.
Carry out the checks before starting up, see chapter 5
"Starting/Stopping", observing the maintenance programme frequencies.
ITEM
NOTES
Intake filter
2
Pipes
Belts and/or pulleys, joints
Bolt nuts and fixing elements
Oil leaks
Water leaks
Oil level
First oil change
Oil change
1
Oil seals
4..5
Water seals
3..4
Water seal assembly
4
Valves unit
4
Pumping unit
Accessories
38
FREQUENCY
HOURS
DAILY
WEEKLY
50 500 1500 3000
I
C
I
I
I
I
I
I
R
R
I
L
R
I
I
I
- Reproduction forbidden -
I: check and clean, adjust, lubricate, replace if necessary
C: clean
R: change
L: lubricate
R
1. Change the oil at least once a year.
2. Clean according to clogging which depends on the specific working conditions of
R
each application.
3. Lubricate the seals on those models featuring a greaser.
R
4. Change according to wear which depends on the specific working conditions of each
R
application.
5. We recommend changing the oil sealing rings every 3 years.